QIAsymphony RGQ

用于整合的自动纯化、反应体系构建和检测,满足分子检测所需

S_1951_IAS_QSYMRGQ_s

✓ 全天候自动处理在线订单

✓ 博学专业的产品和技术支持

✓ 快速可靠的(再)订购

QIAsymphony RGQ, System

Cat. No. / ID:   9001850

QIAsymphony SP, QIAsymphony AS, Rotor-Gene Q 5plex HRM; includes required accessories and consumables, installation, and training; includes 1-year warranty on parts and labor
仪器附件
QIAsymphony RGQ System
QIAsymphony Cabinet SP/AS
QIAsymphony SP核酸提取纯化分析仪应与可与其兼容的QIAsymphony Kits配合使用,适用于试剂盒使用手册中指定的应用。QIAsymphony AS应与可与其兼容的QIAGEN Kits配合使用,适用于试剂盒使用手册中指定的应用。如果将QIAsymphony AS 与非QIAGEN的试剂盒配合使用,用户应自行确认是否适用于相关应用。Rotor-Gene Q实时荧光定量PCR分析仪应与可与其兼容的QIAGEN Kits配合使用,适用于试剂盒使用手册中指定的应用。如果将Rotor-Gene Q实时荧光定量PCR分析仪与非QIAGEN的试剂盒配合使用,用户应自行确认是否适用于相关应用。

✓ 全天候自动处理在线订单

✓ 博学专业的产品和技术支持

✓ 快速可靠的(再)订购

特点

  • 前所未有的灵活性
  • 优化的操作流程,高实用性
  • 易于操作,提供最大程度的便利性
  • 监控分析和实验室开发测试
  • 适合多种应用

产品详情

新的QIAGEN工作流程包括用于样本制备的QIAsymphony SP核酸提取纯化分析仪、用于反应体系构建的QIAsymphony AS以及在Rotor-Gene Q实时荧光定量PCR分析仪上进行的一系列即用型分析。QIAGEN将进一步研发、拓展QIAsymphony系列产品。

绩效

QIAsymphony RGQ配合artus QS-RGQ Kits,应用于多种高灵敏度、高特异性检测:

原理

QIAsymphony RGQ可处理多达96个样本,从样本到结果只需一次完整的自动化运行,节省时间。一系列专门的试剂盒可组成分子检测的开放或封闭系统。

QIAsymphony SP/AS仪器和Rotor-Gene Q实时荧光定量PCR分析仪配合形成了一个可自动完成工作流程的完整系统。QIAsymphony SP核酸提取纯化分析仪可自动完成各种类型样本的制备。QIAsymphony AS确保构建的PCR反应体系高度可靠且重复性好,适合每日需要进行复杂PCR分析的实验室。QIAsymphony AS可对每次运行或样本进行多重体系构建,支持artus QS-RGQ的产品,完全兼容CE-IVD标准的工作流程,也支持自己设定的工作流程。Rotor-Gene Q实时荧光定量PCR分析仪可配合CE-IVD-marked的artus QS-RGQ试剂盒或自己设定的工作流程进行敏感、精确的real-time PCR分析。

在QIAsymphony RGQ上完全兼容CE-IVD标准的试剂盒
试剂盒仪器方法
QIAsymphony DSP Virus/Pathogen KitsQIAsymphony SP核酸提取纯化分析仪从多种类型的样本中纯化病毒核酸或细菌DNA
artus QS-RGQ KitsQIAsymphony ASReal-time PCR(多重;样本和内参)
在QIAsymphony RGQ上适合自己设定工作流程测试的试剂盒
应用试剂盒仪器方法
纯化QIAsymphony DSP Virus/Pathogen KitsQIAsymphony SP核酸提取纯化分析仪从各种类型样本中纯化病毒核酸或细菌
QIAsymphony DSP AXpH DNA KitQIAsymphony SP核酸提取纯化分析仪从细胞培养悬浮液中纯化病毒核酸或细菌
QIAsymphony Certal KitsQIAsymphony SP核酸提取纯化分析仪从生物纯化缓冲液、细胞培养悬浮液样本和疫苗制备样本中纯化宿主残留DNA和病毒核酸
反应体系构建
—病原体检测
QuantiFast Pathogen +IC KitsQIAsymphony AS使用序列特异性探针进行多重real-time PCR和RT-PCR
QuantiTect Virus KitsQIAsymphony AS可在单管中高度灵敏的检测多种病毒DNA和RNA
QIAGEN OneStep RT-PCR KitQIAsymphony AS使用任何RNA模板,简单设置,进行灵敏的RT-PCR
反应体系构建
—基因表达
Rotor-Gene SYBR® Green KitsQIAsymphony AS使用SYBR® Green I进行超快速、精确的real-time PCR和RT-PCR
Rotor-Gene Probe KitsQIAsymphony AS使用序列特异性的探针进行超快速、精确的real-time PCR和RT-PCR
Rotor-Gene Multiplex KitsQIAsymphony AS使用序列特异性的探针进行超快速、精确的多重real-time PCR和RT-PCR
反应体系构建
—残留DNA 检测
Certal Detection KitsQIAsymphony AS多重real-time PCR检测残留DNA和内参

程序

QIAsymphony RGQ工作流程的开始是在QIAsymphony SP仪器上纯化核酸。从样本制备流程中得到的含纯核酸的洗脱液转移到QIAsymphony AS模块,进行分析体系构建。分析样本再转移到Rotor-Gene Q实时荧光定量PCR分析仪进行PCR和数据分析。

为了满足不同工作流程需要,操作系统中有两种模式:完整模式或独立模式。在完整模式中,样本在QIAsymphony SP核酸提取纯化分析仪处理后直接转移到QIAsymphony AS,减少了手工操作步骤和记录。为了增加灵活性,QIAsymphony SP核酸提取纯化分析仪和AS也可在独立模式中进行相互独立的操作。参见"QIAsymphony workflows"。

应用

QIAsymphony RGQ是目前和将来用于各种分子检测的最具有多功能性的系统。QIAsymphony RGQ在一个平台上整合了多种分析,也能进行自行开发测试。

适合于开放和闭合系统多种应用,包括:

  • artus移植面板(CMV、EBV、HSV、BK病毒和VZV)
  • artus血源性病毒面板(HIV、HCV和HBV)
  • 内部测试

辅助数据和图表

Specifications

FeaturesSpecifications
Elution volumeQIAsymphony SP, 50–400 µl (application/protocol dependent)
Overvoltage categoryII
Samples per run (throughput)Tubes 0.2 ml; Strip Tubes 0.1 ml (4 tubes); Rotor-Disc 72; Rotor-Disc 100; Up to 100 samples per run using a Rotor-Disc 100
Storage temperature5-40°C in manufacturer's package
ProcessingAutomated
Pollution level2
FeaturesDynamic range, 12 orders of magnitude
HumidityRelative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C
Instrument dimensionsQIAsymphony SP, 130 x 75 x 103 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm
Operating temperature15-32°C
Heat dissipation/thermal loadAverage, 0.183 kW (632 BTU/hour); Peak, 0.458 kW (1578 BTU/hour)
Place of operationFor indoor use only
SoftwareRotor-Gene Q software, supplied on the installation CD provided
TechnologyQIAsymphony SP — QIAGEN magnetic-particles chemistry
Protocols/main application on this instrumentQIAsymphony SP — Purification of DNA, RNA, bacterial and viral nucleic acids, and 6xHis-tagged protein from a wide range of starting materials; QIAsymphony AS — PCR setup.
Power100-240 V AC, 50-60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages
Input volumeQIAsymphony SP, 100-1000 µl (application/protocol dependent)
Kits or Application Packs designed for this instrumentQIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits
Optical SystemUp to 6 channels spanning UV to infra-red wavelengths; Excitation sources: High energy light-emitting diodes; Detector: Photomultiplier; Acquisition time: 4 s. The software allows to create new excitation/detection wavelength combinations
Thermal performanceTemperature range, 35 to 99ºC; Temperature accuracy, ±0.5ºC (type, measured 30 seconds after clock start); Temperature resolution, ±0.02ºC (smallest programmable increment); Temperature uniformity, ±0.02ºC; Ramp rate (peak ramp rates, air), >15ºC/s heating, >20ºC/s cooling
Typical run time40 cycles in 45 min with the QIAGEN RG Kits (assay dependent)
WeightQIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg
Transportation conditions-25-70°C in manufacturer's package
Warranty1 year on instrument; lifetime guarantee on excitation LEDs

资源

应用与实验方案 (28)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
Supporting Software and Tools (1)
For QIAsymphony software version 5.0.4
实验方案软件 (7)
For use with the QIAsymphony SP/AS instruments (software version 5.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 5.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
用户使用手册 (6)
For use with QIAsymphony SP/AS instruments (software version 5.0)
Guideline for ISO 20836:2020
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
仪器技术参数 (10)
QIAsymphony Cabinet SP/AS documents
Differences between QIAsymphony software versions
For use with QIAsymphony SP/AS instruments (software version 5.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
QIAsymphony Cabinet SP/AS document
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Software document for QIAsymphony software version 4.0.1
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
试剂盒操作手册 (1)
artus EBV QS-RGQ Kit Handbook
Labware Files and Documents (2)
Labware package SOW-516-0-09 for use with the QIAsymphony SP/AS instruments (software version 5.0)
产品介绍与指南 (1)
Safety Data Sheets (1)
Certificates of Analysis (1)

FAQ

The QIAsymphony RNA kit uses RLT plus as lysis buffer. Can samples lysed in RLT and then stored in the freezer be used on the QIAsymphony?

The RLT buffer is more viscous than the RLT plus buffer. Extraction will work fine, but there may be some magnetic bead carryover to the eluate.

FAQ ID - 3533
There is no barcode on the QIAsymphony cooling adapter, and the instrument asks for one. What do you suggest I do?

The barcode on the adapter at the cooling elution position is read by default. This can be changed in the configuration settings which are available from the tools menu if you have logged in as Supervisor. The option is on the tab Process SP1 and is called ”On which elution slots should the bar codes be scanned”. To disable the barcode reading, put the setting to ”none”.

FAQ ID - 3532