EZ1 RNA Tissue Mini Kit

自动纯化高品质总RNA

S_1294_9_LS_QF_EZ1_2_RNA_Tissue_Mini_Kit_48

✓ 全天候自动处理在线订单

✓ 博学专业的产品和技术支持

✓ 快速可靠的(再)订购

EZ1&2 RNA Tissue Mini Kit (48)

Cat. No. / ID:   959034

For 48 preps: Reagent Cartridges (Tissue RNA), Disposable Filter-Tips, Disposable Tip-Holders, Sample Tubes (2 ml), Elution Tubes (1.5 ml), Buffer RLT, RNase-free DNase I, RNase-free water
SEK 5,650.00
登录 要查看您的账户定价。
The name of this kit was changed from "EZ1 RNA Tissue Mini Kit" to "EZ1&2 RNA Tissue Mini Kit" to demonstrate that it is compatible with the new EZ2 Connect instruments as well as the EZ1 Advanced XL. No changes were made to the well-established kit technology.
EZ1 RNA Tissue Mini Kit 旨在用于分子生物学应用。该产品不能用于疾病诊断、预防和治疗。

✓ 全天候自动处理在线订单

✓ 博学专业的产品和技术支持

✓ 快速可靠的(再)订购

特点

  • 纯化多达30 μg的总RNA
  • 可靠地处理多达10 mg的标准组织样本
  • 无RNase污染,结果可靠
  • 洗脱体积可调
  • 程序设置简单,插卡即用

产品详情

EZ1 RNA Cell Tissue Kit利用磁珠技术可从多达10 mg的标准组织样本中自动纯化总RNA,试剂盒包含所有需要的试剂和耗材。纯化试剂预先封填在试剂条中,以确保可快速、便利的加载至仪器中。EZ1 RNA Tissue Mini Kit可用在EZ1 Advanced XL、EZ1 Advanced或BioRobot EZ1工作站上。

绩效

使用EZ1 RNA Tissue Mini Kit纯化获得高产量、高品质总RNA的稳定性好、重复性高(参见" Efficient purification and reproducible yields"和" Consistent highly pure RNA")。

查看图表

原理

使用EZ1 RNA Tissue Mini Kit进行自动纯化需使用EZ1 Advanced XL和EZ1 Advanced XL RNA Card,EZ1 Advanced和EZ1 Advanced RNA Card或BioRobot EZ1和EZ1 RNA Card。EZ1卡预装有纯化程序,在控制面板提供操作向导,并提供工作站的运行指令。

仪器使用硅胶膜磁珠技术,可在一次操作中对1–14个样本(EZ1 Advanced XL)或1–6个样本(EZ1 Advanced和BioRobot EZ1)进行纯化。预封装的试剂条和仪器的自动感控锁可降低污染的风险,避免RNases导致的核酸降解。自动纯化流程重复性好、产量线性契合度高,覆盖宽范围的起始样本量。该试剂盒可从各种不同的组织样本类型中纯化获得高品质的总RNA,适用于多种基因表达分析的应用。RNA的产量依赖于多种因素,包括:样本量、组织类型和纯化状态。

程序

组织首先放入Buffer RLT中裂解、匀浆。全自动EZ1 RNA纯化操作后,RNA被一步纯化。即使很少量的DNA也会干扰RNA的下游应用,所以采用完整的DNase 裂解步骤去除基因组DNA的污染。总RNA洗脱体积为200 µl、100 µl或50 µl,可直接用于各种下游应用。

应用

EZ1 RNA Tissue Mini Kit纯化得到的高品质RNA适用于各种下游应用,如:

  • 应用real-time RT-PCR技术进行基因表达分析
  • 应用芯片技术进行基因表达分析
  • 肿瘤学和病理学研究

辅助数据和图表

Specifications

FeaturesSpecifications
ApplicationsPCR, real-time RT-PCR, microarray
Time per run or per prep40 minutes
TechnologyMagnetic particles
Elution volume50–200 µl
ProcessingAutomated
FormatSample tube
StabilizationYes
For automated processingBioRobot EZ1
Main sample typeTissue samples
Sample amount5–10 µg
Yield<30 µg
Purification of total RNA, miRNA, poly A+ mRNA, DNA or proteinRNA

资源

产品介绍与指南 (2)
安全数据表 (1)
Download Safety Data Sheets for QIAGEN product components.
试剂盒操作手册 (1)
For purification of total RNA from tissue and cells using EZ1 instruments
Safety Data Sheets (1)
Certificates of Analysis (1)
Brochures & Guides (2)
Kit Handbooks (1)
For purification of total RNA from tissue and cells using EZ1 instruments

FAQ

Is training of lab personnel included with the purchase of a BioRobot EZ1?

Operation of the BioRobot EZ1 is so easy that no additional training other than the initial demo is needed. Operating the instrument requires only three major steps:

  • Insert the appropriate EZ1 Protocol Card, switch on the workstation, and, if necessary, select the appropriate protocol
  • Follow the instructions on the liquid-crystal display (LCD), which describes where the sample tubes, elution tubes, filter tips, and EZ1 Reagent Cartridges must be loaded and which indicates when to start the protocol run
  • Collect purified nucleic acids when the protocol run ends

 

FAQ ID -1239
Are the new EZ1 RNA Kits (cat. no. 958034; 959034; 956034) compatible with the previous EZ1 RNA Card (cat. no. 9015590) or EZ1 RNA Universal Tissue Card (cat. no 9016384)?

No, the new EZ1 RNA Kits can only be used with updated protocols programmed on the new EZ1 RNA Card V2.0.

The new card contains all protocols available for the isolation of RNA on the BioRobot EZ1 with the new kits:

Likewise, the former EZ1 RNA Cell Mini Kit (cat. no. 958134), EZ1 RNA Tissue Mini Kit (cat. no. 959134) and EZ1 RNA Universal Tissue Kit (cat. no. 956136) are not compatible with the new EZ1 RNA Card (cat. no. 9015590).

FAQ ID -1025
Do you have a protocol for the isolation of total nucleic acids from animal and human tissues on the BioRobot EZ1?
How can we get our BioRobot EZ1 upgraded when new protocols are launched?

Protocols for nucleic acid purification are supplied on pre-programmed EZ1 Protocol Cards. These protocols provide both on-screen instructions for the operator and operating commands for the workstation. The range of kits and protocols for the EZ1 is continuously expanding to allow nucleic acid purification from a wide range of sample types. Please browse our Supplementary Protocol Section to find specialized EZ1 protocols for a large variety of clinical sample types, in addition to the standard sample types covered in our EZ1 handbooks.

 

FAQ ID -1241
Where can I find information about the worktable setup on the BioRobot EZ1?

Loading of sample tubes, elution tubes, filter-tips, and Reagent Cartridges onto the worktable of the BioRobot EZ1 is intuitive, easy and quick. Details about worktable setup are provided with each new protocol, and are also displayed in the liquid-crystal display (LCD) of the control panel when you start setup of the worktable.

 

FAQ ID -1243
Do the foils sealing the EZ1 Reagent Cartridges have to be manually removed prior to loading the robot?

No, prefilled Reagent Cartridges can be loaded onto the BioRobot EZ1 with their seals. During operation of the instrument, the piercing unit, a row of 6 metal spikes located behind the tip adapters, will puncture the foil of the cartridges, thereby exposing the reagents.

 

FAQ ID -1240
What has to be done to an RNA sample before loading it onto an Agilent Bioanalyzer?

For RNA isolated on the BioRobot EZ1 and BioRobot M48:

The RNA can be directly applied to the Agilent Bioanalyzer, since it is being denatured in the final protocol steps of these isolation procedures.

For RNA prepared with all other QIAGEN RNA Isolation Products:

We recommend to denature the samples in a water bath for 2 min at 70°C, and then place them directly on ice prior to loading them onto the Agilent Bioanalyzer.

 

FAQ ID -528
Do you have a protocol for the isolation of total RNA from paraffin-embedded sections on the BioRobot EZ1?
FAQ ID -976
Do you have a protocol for the isolation of DNA from fungi using the BioRobot EZ1?
Yes, please follow the Supplementary Protocol 'Purification of DNA from fungi using the EZ1 DNA Tissue Kit' (MA35).
FAQ ID -992
How do I safely inactivate biohazardous flow-through material?

Always dispose of potentially biohazardous solutions according to your institution’s waste-disposal guidelines. Although the lysis and binding buffers in QIAamp, DNeasy, and RNeasy kits contain chaotropic agents that can inactivate some biohazardous material, local regulations dictate the proper way to dispose of biohazards. DO NOT add bleach or acidic solutions directly to the sample-preparation waste. Guanidine hydrochloride in the sample-preparation waste can form highly reactive compounds when combined with bleach.
Please access our Material Safety Data Sheets (MSDS) online for detailed information on the reagents for each respective kit.

FAQ ID -12
What disposables are required for nucleic acid isolations on the BioRobot EZ1?

No extra accessories need to be purchased for the BioRobot EZ1, as sample and elution tubes, as well as tips and tip holders are included with each EZ1 DNA or RNA isolation kit.

 

FAQ ID -1246