To ensure sensitivity, artus HI Virus-1 Kits have been optimized to detect low numbers of HIV-1 RNA. The analytical sensitivity of the artus HI Virus-1 QS-RGQ Kit is 76.4 IU/ml in consideration of the purification and assay setup using the QIAsymphony RGQ system (see figure " Sensitive detection of HIV-1 RNA").
For reliable specificity, testing of the artus HI Virus-1 Kits was carried out using various HIV-1 isolates, including all group M subtypes A–H, and related pathogens.
Kit | artus HI Virus-1 RG RT-PCR Kit | artus HI Virus-1 QS-RGQ Kit |
---|---|---|
Sample type | EDTA plasma | EDTA plasma |
Analytical sensitivity | 66.9 IU/ml | 76.4 IU/ml |
Linear range | 120 to >1 x 108 IU/ml | 250 to 108 IU/ml |
Specificity | HIV-1, including all group M subtypes A–H | HIV-1, including all group M subtypes A–H |
The artus HI Virus-1 RG RT-PCR Kit and the artus HI Virus-1 QS-RGQ Kit are based on the amplification and simultaneous detection of a specific region of the HIV-1 genome using real-time RT-PCR. The kits provide high levels of specificity and sensitivity (see figure " Sensitive detection of HIV-1 RNA") over a broad linear range.
Each artus HI Virus-1 Kit provides 4 HIV-1 quantitation standards (see figure " Reliable quantitation of HIV-1 load"). Use of the standards enables accurate quantitation of viral load. In addition, the kits contains a second heterologous amplification system to identify possible PCR inhibition. This is detected as an internal control (IC) in a different fluorescence channel from the analytical PCR. The detection limit of the analytical HIV-1 PCR is not reduced.
Kit | artus HI Virus-1 RG RT-PCR Kit and artus HI Virus-1 QS-RGQ Kit |
---|---|
Sample type | EDTA plasma |
Amplicon | 93 nt region of the 5' LTR |
artusHI Virus-1 RT-PCR Kits provide all necessary reagents optimized for reliable HIV-1 RNA detection and quantitation. Simply add template RNA to the ready-to-use PCR master mix, and start the reaction on the appropriate real-time cycler using the optimized cycling program described in the kit handbook.
The QIAsymphony RGQ workflow solution for HIV-1 detection comprises the QIAsymphony SP for sample preparation, the QIAsymphony AS for assay setup, and the artus HI Virus-1 QS-RGQ Kit on the Rotor-Gene Q. The system enables reliable pathogen detection with a complete workflow (see figure " Integrated QIAsymphony RGQ system for HIV-1 detection").
For the artus HI Virus-1 RG RT-PCR Kit, we recommend using the QIAamp DSP Virus Kit.
The artus HI Virus-1 RG RT-PCR Kit enables rapid and sensitive detection and quantitation of HIV-1 RNA purified from plasma using the QIAamp DSP Virus Kit.
The artus HI Virus-1 QS-RGQ Kit is designed to be used with the QIAsymphony RGQ system, providing a complete workflow from sample to HIV-1 RNA detection and quantitation.