QIAsymphony Virus/Bacteria Kits

从1–96个样本中自动纯化病毒核酸或细菌DNA

Products

QIAsymphony Virus/Bacteria Kits 旨在用于分子生物学应用。这些产品不能用于疾病诊断、预防和治疗。
Image

QIAsymphony Virus/Bacteria Midi Kit (96)

Cat. No. / ID:   931055

For 96 preps of 1000 µl each: includes 2 reagent cartridges and enzyme racks and accessories
Image

QIAsymphony Virus/Bacteria Mini Kit (192)

Cat. No. / ID:   931036

For 192 preps of 200 µl each: includes 2 reagent cartridges and enzyme racks and accessories

特点

  • 标准化的处理流程保证高度重复性
  • 条形码扫描可追踪样本和试剂
  • 经优化的操作流程确保高产量高纯度的核酸
  • 新型预装试剂条,操作简便

产品详情

QIAsymphony Virus/Bacteria Kit可在QIAsymphony SP核酸提取纯化分析仪上,从多种类型样本中自动纯化病毒核酸和细菌DNA。例如,可以从血浆、血清、脑脊液、呼吸道样本、尿常规样本、泌尿生殖道拭子和运输介质中纯化核酸。试剂盒有小型和中型规格,对应样本体积200 μl和至多1000 μl。经优化的实验方案提供高产量高纯度的核酸,和灵活的洗脱体积,因而可以根据每个下游应用,优化调整核酸浓度。新型的预装试剂条减少了工作站设置时间,并减少了手动操作。条形码阅读器进行试剂全程跟踪。

绩效

QIAsymphony Virus/Bacteria Kit可以准确、重复地的纯化核酸。经纯化的病毒和细菌核酸没有蛋白质、核酸酶和其他杂质,适用于敏感的下游应用。高产量和灵活的洗脱体积(60 μl、85 μl或者110 μl)符合下游应用的要求,适用于敏感的分析检测(参见" Sensitive detection of Chlamydia trachomatis in urine")。
查看图表

原理

QIAsymphony Virus/Bacteria Kit将硅胶膜纯化病毒和细菌核酸的速度、效率与易于操作的磁性颗粒相结合(参见" Efficient processing of magnetic particles")。创新的即用型试剂条预装有磁性颗粒和纯化步骤所需的所有试剂,包括附加的酶,以及可在QIAsymphony SP核酸提取纯化分析仪上被自动打开的试剂,可较大程度降低污染的风险(参见" Prefilled, sealed reagent cartridges")。台面设置快速,节省你的宝贵时间。只需简单地在试剂置入模块中加载至多2个试剂条。试剂条可以来自相同的试剂盒,也可以是不同的试剂盒,因此可在处理96个样本的同一批次中,运行不同的纯化步骤。试剂仅会用于所选数目的样本,实现成本控制。
查看图表

程序

纯化操作流程的目的在于确保安全、可重复的处理传染性样本,包括4个步骤:裂解、结合、洗涤和洗脱。用户可以选择不同的洗脱体积,取决于实验方案。在QIAsymphony SP核酸提取纯化分析仪上可完成所有纯化流程的步骤。每次运行至多可以处理96个样本。

QIAsymphony Virus/Bacteria实验方案
实验方案 试剂盒 样本材料处理体积
Cellfree 200   QIAsymphony Virus/Bacteria Mini Kit (192) 血浆、血清和脑脊液 200 μl
Cellfree 500    QIAsymphony Virus/Bacteria Midi Kit (96)  血浆、血清和脑脊液 500 μl
Cellfree 1000    QIAsymphony Virus/Bacteria Midi Kit (96)  血浆、血清和脑脊液 1000 μl
Complex 200   QIAsymphony Virus/Bacteria Mini Kit (192)   呼吸道样本(BAL、干拭子、传输介质、呼出物、痰)和泌尿生殖系统的样品(尿液、运输培养基)  200 μl
Complex 400   QIAsymphony Virus/Bacteria Midi Kit (96)   呼吸道样本(BAL、干拭子、传输介质、呼出物、痰)和泌尿生殖系统的样品(尿液、运输培养基) 400 μl 
Complex 800     QIAsymphony Virus/Bacteria Midi Kit (96) 呼吸道样本(BAL、干拭子、传输介质、呼出物、痰)和泌尿生殖系统的样品(尿液、运输培养基) 800 μl 

应用

QIAsymphony Virus/Bacteria Kit能够灵敏的检测多种DNA和RNA病毒以及细菌病原体。产量呈线性,准确的定量分析高和低的病毒或者细菌滴度。高品质的核酸可即用于各种下游应用,包括定量real-time PCR或者RT-PCR等敏感的应用。

辅助数据和图表

Specifications

FeaturesSpecifications
ApplicationsPCR, real-time PCR
Elution volume60-110 µl
Purification of total RNA, miRNA, poly A+ mRNA, DNA or proteinPurification of viral RNA and DNA and bacterial DNA
Input volume800 µl (Pathogen Complex Protocol); 1000 µl (Virus Cellfree Protocol)
TechnologyMagnetic particles
Sample typesSerum, plasma, CSF, cell-free body fluids, fresh or frozen material (body fluids, swabs, secretions, tissues, stool specimens)

资源

安全数据表 (1)
Download Safety Data Sheets for QIAGEN product components.
Technical Information and Important Notes (1)
Labware Files and Documents (2)
For use with the QIAsymphony SP/AS instruments (software version 4.0)
For use with software version 5.0 or higher 
应用与实验方案 (9)
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
For use with software version 4.0 or higher 
试剂盒操作手册 (1)
Safety Data Sheets (1)
Certificates of Analysis (1)

FAQ

Does an internal control have to be included for each QIAsymphony Virus/Bacteria protocol run?

No. The use of internal controls with the QIAsymphony Virus/Bacteria Kits is not mandatory. When using internal controls, they are added to the carrier RNA mixture (total volume of the mixture must be 120 µl).

 

FAQ ID -2040
Which QIAsymphony Virus/Bacteria Kit size should be used for each protocol?

The QIAsymphony Virus/Bacteria Mini Kit is used with the 'Cellfree_200' and 'Complex_200' protocols.

The QIAsymphony Virus/Bacteria Midi Kit is used with the 'Cellfree_500’, 'Cellfree_1000', ‘Complex_400’ and 'Complex_800' protocols.

FAQ ID -2038
What sample types can be processed using the QIAsymphony Virus/Bacteria protocols?

Plasma, serum, and CSF samples can be processed using the Virus Cellfree protocols of the QIAsymphony Virus/Bacteria Kits. Respiratory samples (sputum, BAL, aspirates, dried swabs, transport media), and urogenital samples (urine, urogenital swabs, transport media) can be processed using the Pathogen Complex protocols.

 

FAQ ID -2036
What sample types can be processed using the QIAsymphony DSP Virus/Pathogen protocols?
Plasma, serum, and CSF samples can be processed using the QIAsymphony DSP Virus/Pathogen cellfree protocols. Respiratory samples (sputum, BAL, aspirates, dried swabs, transport media), and urogenital samples (urine, urogenital swabs, transport media) can be processed using the pathogen complex protocols.
FAQ ID -2928
What sample volumes can be processed with the QIAsymphony Virus/Bacteria Kits?

Sample volumes that can be processed with the QIAsymphony Virus/Bacteria Kits depend on the protocol:

  • 'Cellfree_200' and 'Complex_200':  200 µl
  • 'Complex_800':                            800 µl
  • 'Cellfree_1000':                           1000 µl

 

FAQ ID -2037
Do QIAsymphony Virus/Bacteria samples require pretreatment before they are loaded onto the instrument?

Pre-treatment of samples used with the QIAsymphony Virus/Bacteria Kits can improve nucleic acid extraction for some sample types. Viscous samples (e.g., sputum, respiratory aspirates) might require liquefaction to enable pipetting. Pretreatment protocols are provided in the QIAsymphony Virus/Bacteria Handbook.

 

FAQ ID -2039