Rotor-Gene AssayManager v2.1

New Rotor-Gene AssayManager v2.1 software for QIAGEN IVD assays only.
For routine testing with Rotor-Gene Q MDx instruments.

S_1084_5_GEN_V2

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Rotor-Gene AssayManager v2.1 License (1)

Cat. No. / ID:   9025620

Single license for the installation of Rotor-Gene AssayManager v2.1 software on one computer. For installation on multiple computers, each computer requires an individual computer-specific license key.Visit the Download Page for software download, installation and licensing instructions.
Software
Rotor-Gene AssayManager v2.1 License
Rotor-Gene AssayManager v2.1
For up-to-date licensing information or Rotor-Gene Q MDx instrument specific disclaimers, refer to the corresponding Rotor-Gene Q MDx instrument user manual.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Standardized, fully automated real-time PCR analysis
  • Maximized process safety and ease of use
  • Enhanced lab productivity with optimized workflow

Product Details


IMPORTANT:
  • Rotor-Gene AssayManager v2.1 is a unique software platform and it is not an update for Rotor-Gene AssayManager v1.0
  • Rotor-Gene AssayManager v2.1 requires distinct plug-ins that are not compatible with Rotor-Gene AssayManager v1.0
  • Rotor-Gene AssayManager v2.1 is not compatible with Rotor-Gene AssayManager v1.0 plug-ins
  • Rotor-Gene AssayManager v2.1 cannot run on the same computer as Rotor-Gene AssayManager v1.0 software

Rotor-Gene AssayManager v2.1 software is used in combination with Rotor-Gene Q MDx instruments for routine testing. This intuitive software manages all tasks associated with running real-time PCR assays offering enhanced convenience, standardization, and flexibility. Fully automated analysis and interpretation of results minimizes human error, delivering results you can trust.

Principle

Rotor-Gene AssayManager v2.1 is able to read in sample information, set up experiments, control up to 4 different Rotor-Gene Q MDx cyclers, acquire data from these instruments, automatically analyze results and create reports. The information on how to run, analyze, interpret and report an assay is stored in the Rotor-Gene AssayManager v2.1 database. Comprehensive user guidance and well-defined workflows facilitate increased standardization and laboratory productivity. In addition, Rotor-Gene AssayManager v2.1 supports the latest quality and usability requirements for software, such as 21 CFR Part 11.
Rotor-Gene AssayManager v2.1 enables:
  • Operation of up to 4 Rotor-Gene Q MDx cyclers from one computer
  • Individual or network installation with remote access
  • Reliable data management
  • Secure user management
  • Fully automated analysis and interpretation of results
  • Validated workflows for QIAGEN IVD assays

Procedure

Comprehensive user guidance with flexible options
Rotor-Gene AssayManager v2.1 operates in a Closed Mode. Color schemes, easy-to-understand icons, and comprehensive help and warning messages guide the user step-by-step through the software.
Control of up to 4 Rotor-Gene Q MDx cyclers and remote access
Rotor-Gene AssayManager v2.1 controls the Rotor-Gene Q MDx cycler, i.e., the software will provide all functions to set up, start and run real-time PCR experiments on up to 4 Rotor-Gene Q MDx cyclers in parallel. This saves laboratory space and increases lab efficiency.
Rotor-Gene AssayManager v2.1 can also be used for experiment setup or reporting on computers not connected to a Rotor-Gene Q MDx cycler. In this case, the software can be installed on the user's office computer. Alternatively, a computer in the assay setup room may be used for run setup. This networking capability together with secure database management simplifies a variety of everyday tasks.
Fully automated real-time PCR analysis
Automated real-time PCR analysis is the core function of Rotor-Gene AssayManager v2.1. Rotor-Gene AssayManager analyzes the real-time PCR raw data according to well-defined assay specific rules and generates result reports comprising information on the validity or invalidity of the assay and individual samples.
The unique Automatic Data Scan (AUDAS) compares real-time data with performance characteristics established by statistical methods during assay development. This feature detects assay deviations and artifacts that cannot be monitored by the assay controls alone, ensuring best-in-class, error-free real-time PCR analysis.
Reliable data management
Data from each installation and from all Rotor-Gene Q MDx cyclers in your lab are stored in a central database. After analysis and reporting (e.g., as a printout, PDF or LIMS export), data is moved to a common electronic archive. For fast and easy data access, the database is searchable by using various filter functions.
Secure user management
Different user profiles are available and are password protected (user login is required) for increased security. Operators set up and start a run, while administrators are responsible for managing all assets (e.g., cyclers, assay profiles, users) necessary for working with Rotor-Gene AssayManager v2.1. Assignment of these dedicated user roles enables optimal use of resources for your laboratory tasks.
Support of 21 CFR Part 11 compliance
Rotor-Gene AssayManager v2.1 includes specific features that support the technical requirements of 21 CFR Part 11 regulations, enabling use of an electronic records system. User accounts are password-protected, including special security requirements, and user actions are documented in an audit trail that can be filtered and printed out. The Rotor-Gene AssayManager 2.1 audit trail is designed based on guidelines in FDA CFR Title 21, Part 11 Electronic Records, Electronic Signatures.
Software that meets the demands of routine testing applications — today and tomorrow
Rotor-Gene AssayManager v2.1 standardizes procedures such as cycler control and data storage, helping to reduce the burden of multiple standard operating procedures and simplifying laboratory documentation. Full flexibility is retained through the use of modular plug-ins that ensure future assays and different assay designs can be run with the workflow already established in your laboratory.

Applications

Rotor-Gene AssayManager v2.1 enables fully automated analysis of validated QIAGEN IVD assays in routine testing laboratories.

Software

To download Rotor-Gene AssayManager v2.1 after purchase:

    Click the "Download" button and follow the on-screen instructions to install Rotor-Gene AssayManager v2.1.
    Rotor-Gene AssayManager v2.1 and license must be purchased prior to use.
    IMPORTANT: In order to perform and analyze runs, at least one Rotor-Gene AssayManager v2.1 plug-in needs to be installed. Refer to your assay kit handbook for more information.

To purchase a license key for Rotor-Gene AssayManager v2.1:

    1. After purchasing Rotor-Gene AssayManager v2.1 software and licenses, click the "Download" button and follow the onscreen instructions to install. After successful installation of the Rotor-Gene AssayManager v2.1 and a plug-in, a “key file” will be generated. This "key file" will be attached to the "Technical Support Form" in Step 5, below.
    2. Go to the Technical Support Form. Make sure to include all required information and your Rotor-Gene Q MDx serial number when filling out the form.
    3. For Question 2, "Type of Request", select “Other”.
    4. For Question 4, “Your inquiry”, enter "Rotor-Gene AssayManager v2.1 license request” and include your purchase order number, from your order confirmation.
    5. Include the "key file" from Step 1 as an attachment.
    6. Submit the form. QIAGEN Technical Services will respond via email with a license file within 1–2 working days.
    7. After receiving your computer-specific Rotor-Gene AssayManager v2.1 license file, archive the license file locally on your computer.
IMPORTANT: The license file must always exist on the computer that has Rotor-Gene AssayManager v2.1 installed. The license file location should be protected and not subject to change.

Supporting data and figures

Resources

Operating Software (2)
Gamma MDx Plug-in for use with Rotor-Gene AssayManager v2.1 MDx (US)
To download Rotor-Gene AssayManager v2.1.1 after purchase:
    Click the Rotor-Gene AssayManager v2.1.1 Software header. On the next window, click Continue. Follow the on-screen instructions to install Rotor-Gene AssayManager v2.1.1.
    Rotor-Gene AssayManager v2.1.1 and license must be purchased prior to use.    

    IMPORTANT: In order to perform and analyze runs, at least one Rotor-Gene AssayManager v2.1.1 plug-in needs to be installed. Refer to your assay kit handbook for more information.

    IMPORTANT: To allow checksum integrity verification, use the value D24F10DEB7A1D60EE381E2AEA8789117D0980FCC.

To purchase a license key for Rotor-Gene AssayManager v2.1.1:
    1. After purchasing Rotor-Gene AssayManager v2.1.1 software and licenses, click the "Download" button and follow the onscreen instructions to install. After successful installation of the Rotor-Gene AssayManager v2.1.1 and a plug-in, a “key file” will be generated. This "key file" will be attached to the "Technical Support Form" in Step 5, below.   
    2. Go to the Technical Support Form. Make sure to include all required information and your Rotor-Gene Q or Rotor-Gene Q MDx serial number when filling out the form.       
    3. For Question 2, "Type of Request", select “Other”.
    4. For Question 4, “Your inquiry”, enter "Rotor-Gene AssayManager license request” and include your purchase order number, from your order confirmation.
    5. Include the "key file" from Step 1 as an attachment.
    6. Submit the form. QIAGEN Technical Services will respond via email with a license file within 1–2 working days.    
    7. After receiving your computer-specific Rotor-Gene AssayManager v2.1.1 license file, archive the license file locally on your computer.

IMPORTANT: The license file must always exist on the computer that has Rotor-Gene AssayManager v2.1.1 installed. The license file location should be protected and not subject to change.





Instrument User Manuals (1)
For use with Rotor-Gene AssayManager v2.1 Gamma MDx (US) Plug-in
Safety Data Sheets (1)
Certificates of Analysis (1)