TissueLyser Adapter Set 2 x 24

Cat. No. / ID:   69982

Two sets of adapter plates and two racks for use with 2 mL microcentrifuge tubes on the TissueLyser III & II
Accessories
Tube Adapter Sets
Plate Adapter Sets
Holder Set
For
2 mL tubes
5 mL tubes
50 mL tubes
TissueLyser Adapter Sets은/는 분자생물학 분야에 사용하기 위한 것입니다. 이 제품들은 질병의 진단, 예방, 또는 치료 목적으로 사용할 수 없습니다.

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

제품 세부 정보

TissueLyser Adapter Sets are designed for efficient and user-friendly disruption of up to 48 or 192 samples in parallel using the QIAGEN TissueLyser II. The TissueLyser Adapter Set 2 x 24 contains a pair of TL Reaction-Tube Holders, 24-Tube. Each holder holds up to 24 microcentrifuge tubes (2 ml). The use of Safe-Lock tubes is strongly recommended (e.g., Eppendorf 2 ml Safe-Lock micro test tubes). The TissueLyser Adapter Set 2 x 96 is for use with QIAGEN Collection Microtubes (racked) and Collection Microtube Caps. Collection Microtubes are 1.2 ml in volume.

리소스

Supplementary Protocols (3)
Up to 1 x 109 bacteria are disrupted and homogenized by bead-milling in a guanidine-thiocyanate-containing lysis buffer. After addition of ethanol, the sample is loaded onto an RNeasy Mini spin column. Total RNA binds to the RNeasy silica-membrane, contaminants are efficiently washed away, and high-quality RNA is eluted in RNase-free water.
Kit Handbooks (2)
For high-throughput disruption of biological samples
Accessories for the simultaneous disruption of samples in tubes and 96-well plates on the TissueLyser III & II
Safety Data Sheets (1)
Certificates of Analysis (1)

FAQ

Can I precool the TissueLyser 2 x 24 Adapter Set or the 2 x 96 Adapter Set using liquid nitrogen?

We do not recommend using the adapters of the TissueLyser II with liquid nitrogen. Instead, the adapters can be precooled at –80°C, either in the freezer or on dry ice.

FAQ ID -9173
What tubes can be used with TissueLyser Adapter Set 2 x 96 (cat. no. 69984)?

TissueLyser Adapter Set 2 x 96 should be used with Collection Microtubes (racked) and Collection Microtube Caps (cat. nos. 19560 and 19566 respectively).

FAQ ID -3086
Do you have a protocol for purification of total RNA from fatty tissues using QIAzol Lysis Reagent and MaXtract High Density?

Yes, we have the following protocols:

  • Purification of total RNA from fatty tissues using QIAzol Lysis Reagent, MaXtract High Density, and the TissueRuptor (RY29).
  • Purification of total RNA from fatty tissues using QIAzol Lysis Reagent, MaXtract High Density, and the TissueLyser (RY30).
  • Purification of total RNA from fatty tissues using the RNeasy Lipid Tissue Mini Kit and MaXtract High Density (RY31).
FAQ ID -1550
What is the maximum amount of tissue that can be disrupted using the 2 x 24 TissueLyser Adapter Set (cat. no. 69982)?

100 mg tissue per sample tube is the maximum amount we recommend when using the 2 x 24 Adapter Set. Larger amounts of tissue would require considered optimization, depending on the tissue type and condition.

When using 100 mg tissue, for best homogenization results, we recommend cutting the sample into 2 pieces of approximately 50 mg each prior to disruption and performing disruption twice, each time at 25 Hz for 5 min.

FAQ ID -9178