EZ1 RNA Card

BioRobot EZ1 workstation과 EZ1 RNA Kit을 이용하여 RNA purification을 하기 위한 protocol을 쉽게 setup할 수 있습니다

S_1084_5_GEN_V2

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

EZ1 RNA Card

Cat. No. / ID:   9015590

Pre-programmed card for EZ1 RNA purification protocols
SEK 9,800.00
로그인 계정 가격 보기.
EZ1 Cards are used in combination with EZ1 kits on the BioRobot EZ1. Please refer to the specific EZ1 kit handbook and the BioRobot EZ1 User Manual for information about product use.
EZ1 RNA Card은/는 분자생물학 분야에 사용하기 위한 것입니다. 이 제품은 질병의 진단, 예방, 또는 치료용이 아닙니다.

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

특징

  • 손쉬운 프로토콜 셋팅 — 사용이 편리한 카드형 프로토콜
  • 표준화된 processing — preset protocol은 동일한 결과 및 완벽한 set-up 보증
  • 향상된 처리능력 — with protocols for cell and tissue samples
  • Optimized protocols help to ensure reliable purification

제품 세부 정보

The EZ1 RNA Card is a preprogrammed card containing protocols for purification of total RNA or total nucleic acids from cells and easy-to-lyse animal and human tissues, and purification of total RNA from any type of human or animal tissue using EZ1 RNA Kits. These protocols provide both on-screen instructions for the user and operating commands for the BioRobot EZ1.

성능

RNA and nucleic acids purified from cells and tissues with EZ1 RNA kits and the BioRobot EZ1 are of high quality and are suitable for many applications.

원리

The EZ1 RNA Card is a preprogrammed card containing protocols for purification of total RNA or total nucleic acids from cells and easy-to-lyse animal and human tissues. The EZ1 RNA Card is used in combination with EZ1 RNA kits and the BioRobot EZ1 instrument.

절차

Simply insert the EZ1 RNA Card into the BioRobot EZ1 card slot and start the instrument.

응용 분야

The high-quality RNA obtained using the EZ1 RNA Cell Mini Kit, the EZ1 RNA Tissue Mini Kit, or the EZ1 RNA Universal Tissue Kit and the EZ1 RNA Card is suited for use in many applications, such as:

  • Gene expression analysis using real-time RT-PCR technologies
  • Gene expression analysis using microarray technologies
  • Oncology research

FAQ

Is training of lab personnel included with the purchase of a BioRobot EZ1?

Operation of the BioRobot EZ1 is so easy that no additional training other than the initial demo is needed. Operating the instrument requires only three major steps:

  • Insert the appropriate EZ1 Protocol Card, switch on the workstation, and, if necessary, select the appropriate protocol
  • Follow the instructions on the liquid-crystal display (LCD), which describes where the sample tubes, elution tubes, filter tips, and EZ1 Reagent Cartridges must be loaded and which indicates when to start the protocol run
  • Collect purified nucleic acids when the protocol run ends

 

FAQ ID -1239
Are the new EZ1 RNA Kits (cat. no. 958034; 959034; 956034) compatible with the previous EZ1 RNA Card (cat. no. 9015590) or EZ1 RNA Universal Tissue Card (cat. no 9016384)?

No, the new EZ1 RNA Kits can only be used with updated protocols programmed on the new EZ1 RNA Card V2.0.

The new card contains all protocols available for the isolation of RNA on the BioRobot EZ1 with the new kits:

Likewise, the former EZ1 RNA Cell Mini Kit (cat. no. 958134), EZ1 RNA Tissue Mini Kit (cat. no. 959134) and EZ1 RNA Universal Tissue Kit (cat. no. 956136) are not compatible with the new EZ1 RNA Card (cat. no. 9015590).

FAQ ID -1025
Do you have a protocol for the isolation of total nucleic acids from animal and human cells on the BioRobot EZ1?
Do you have a protocol for the isolation of total nucleic acids from animal and human tissues on the BioRobot EZ1?
How can we get our BioRobot EZ1 upgraded when new protocols are launched?

Protocols for nucleic acid purification are supplied on pre-programmed EZ1 Protocol Cards. These protocols provide both on-screen instructions for the operator and operating commands for the workstation. The range of kits and protocols for the EZ1 is continuously expanding to allow nucleic acid purification from a wide range of sample types. Please browse our Supplementary Protocol Section to find specialized EZ1 protocols for a large variety of clinical sample types, in addition to the standard sample types covered in our EZ1 handbooks.

 

FAQ ID -1241
Where can I find information about the worktable setup on the BioRobot EZ1?

Loading of sample tubes, elution tubes, filter-tips, and Reagent Cartridges onto the worktable of the BioRobot EZ1 is intuitive, easy and quick. Details about worktable setup are provided with each new protocol, and are also displayed in the liquid-crystal display (LCD) of the control panel when you start setup of the worktable.

 

FAQ ID -1243
Do the foils sealing the EZ1 Reagent Cartridges have to be manually removed prior to loading the robot?

No, prefilled Reagent Cartridges can be loaded onto the BioRobot EZ1 with their seals. During operation of the instrument, the piercing unit, a row of 6 metal spikes located behind the tip adapters, will puncture the foil of the cartridges, thereby exposing the reagents.

 

FAQ ID -1240
What has to be done to an RNA sample before loading it onto an Agilent Bioanalyzer?

For RNA isolated on the BioRobot EZ1 and BioRobot M48:

The RNA can be directly applied to the Agilent Bioanalyzer, since it is being denatured in the final protocol steps of these isolation procedures.

For RNA prepared with all other QIAGEN RNA Isolation Products:

We recommend to denature the samples in a water bath for 2 min at 70°C, and then place them directly on ice prior to loading them onto the Agilent Bioanalyzer.

 

FAQ ID -528
Do you have a protocol for the isolation of total RNA from paraffin-embedded sections on the BioRobot EZ1?
FAQ ID -976
How do I safely inactivate biohazardous flow-through material?

Always dispose of potentially biohazardous solutions according to your institution’s waste-disposal guidelines. Although the lysis and binding buffers in QIAamp, DNeasy, and RNeasy kits contain chaotropic agents that can inactivate some biohazardous material, local regulations dictate the proper way to dispose of biohazards. DO NOT add bleach or acidic solutions directly to the sample-preparation waste. Guanidine hydrochloride in the sample-preparation waste can form highly reactive compounds when combined with bleach.
Please access our Material Safety Data Sheets (MSDS) online for detailed information on the reagents for each respective kit.

FAQ ID -12
What disposables are required for nucleic acid isolations on the BioRobot EZ1?

No extra accessories need to be purchased for the BioRobot EZ1, as sample and elution tubes, as well as tips and tip holders are included with each EZ1 DNA or RNA isolation kit.

 

FAQ ID -1246