QIAxcel Accessories

DNA fragment 및 RNA 분석용으로 QIAxcel system 사용이 가능합니다

S_1084_5_GEN_V2

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

QX Alignment Marker 15 bp/600 bp (1.5 ml)

Cat. No. / ID:   929530

Alignment marker with 15 bp and 600 bp fragments
AU$161.00
로그인 계정 가격 보기.
Accessories
Marker
Plasticware
Instrument Accessories
Buffer
Type
Alignment
Size
Intensity Calibration
Fragment sizes
15 bp/600 bp
15 bp/1 kb
15 bp/3 kb
15 bp/5 kb
15 bp/10 kb
50 bp/1 kb
50 bp/5 kb
QIAxcel Accessories은/는 분자생물학 분야에 사용하기 위한 것입니다. 이 제품들은 질병의 진단, 예방, 또는 치료 목적으로 사용할 수 없습니다.

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

특징

  • Accessories for automated capillary electrophoresis of DNA samples
  • For use with QIAxcel DNA Kits and a QIAxcel capillary electrophoresis instrument
  • Safety, convenience and a streamlined workflow

제품 세부 정보

QIAxcel accessories are used in combination with QIAxcel instruments for fully automated sensitive, high-resolution capillary electrophoresis of up to 96 samples per run.

리소스

Kit Handbooks (4)
For optimal DNA size determination
For calibrating migration time variation
For automated analysis of DNA fragments using the QIAxcel and QIAxcel Advanced instruments
For calibration of signal intensity
Brochures & Guides (4)

For analysis and typing of PCR products from different HLA loci using the QIAxcel Advanced and the Helmberg-SCORE software

Addressing critical factors and new solutions
A protocol for evaluation of samples for next-generation sequencing on the QIAGEN GeneReader platform using the QIAxcel Advanced Instrument and ScreenGel software version 1.5 of higher
Instrument User Manuals (2)
For use with QIAxcel Advanced instruments and QIAxcel ScreenGel Software version 1.6
Safety Data Sheets (1)
Operating Software (2)
These profiles are intended to be used to run and analyze samples together with the QX DNA Size Marker Large-Fragment Kit (SAP 929710) on the QIAxcel instrument and QIAxcel ScreenGel 1.6 Software.
This release includes the first version of QIAxcel ScreenGel NGS Profiles. These profiles are intended to be used to run and analyze reactions of GeneRead QIAact AIT and BRCA 1/2 panels using the QIAxcel instrument and QIAxcel ScreenGel 1.5 Software. These profiles are composed of an Process Profile, Analysis Profile, Distribution Profile, and Report/Export Profile.
Certificates of Analysis (1)

FAQ

What can be done if lower and upper alignment markers used with the QIAxcel System or QIAxcel Advanced are not aligned correctly?

If lower and upper alignment markers used with the QIAxcel System or QIAxcel Advanced are not aligned correctly, open the channel of the sample that was incorrectly aligned. Check whether any unexpected extra peaks have been detected or if the alignment marker peaks do have any “shoulders” that are detected as separate peaks. Delete any extra peaks if necessary and re-analyze your data.

FAQ ID -1834
Can customers use their own DNA size marker with the QIAxcel System and if yes, what concentration should be used?

The concentration of the DNA marker, pUC18/HaeIII, provided in the QIAxcel DNA Kits is 5ug/ml in 1XTE buffer solution. Customers can run their own DNA size marker sample with different concentration levels using the provided Methods (i.e. M500, H500, L500 and so on).

The recommended method for all basic applications with the QIAxcel System is the M500 method. The BioCalculator software also allows customers to choose their own Sample Injection Time in the Sequence table. The M500 method provides 5KV for 20 seconds for the electro-kinetic injection of lower concentrated DNA samples. If the Injection Time is doubled or tripled (40 or 60 sec), you can expect double or triple intensities (also peak heights).

FAQ ID -1841
When should an intensity calibration be re-performed on the QIAxcel System?

Data for each cartridge intensity calibration on the QIAxcel System is stored in a single file named 'calibration.log'. This file is saved in the BioCalculator root directory C:\Program Files\BioCalculator.

If, for any reason, a different computer is used than the one containing the calibration.log file, the file should be transferred to the new computer. Otherwise, recalibration of the cartridge is required.

Likewise, if the QIAxcel Gel cartridge is used on a different instrument than the one it was calibrated on, another intensity calibration should be performed.

FAQ ID -1825
How can a clogged capillary channel be identified when running samples on the QIAxcel System or QIAxcel Advanced?

If one of the capillaries of the gel cartridge for the QIAxcel System or QIAxcel Advanced is clogged, the corresponding lane in the gel-view image is typically black.

 

FAQ ID -1836