QIAsymphony SP/AS instruments

다양한 종류의 샘플에서 6xHis-tagged recombinant protein 또는 nucleic acid를 전자동으로 분리 정제할 수 있습니다

S_0659_IAS_QSYM

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

QIAsymphony AS

Cat. No. / ID:   9001301

QIAsymphony assay setup module: includes 1-year warranty on parts and labor
기기액세서리
QIAsymphony AS
QIAsymphony SP
QIAsymphony Cabinet
QIAsymphony Cabinet SP/AS
The QIAsymphony SP is intended to be used only in combination with QIAsymphony Kits indicated for use with the QIAsymphony SP for the applications described in the kit handbooks. If used in combination with QIAGEN Kits indicated for use with the QIAsymhony AS instrument, the QIAsymphony AS is intended for the applications described in the respective QIAGEN Kit handbooks. If the QIAsymphony AS instrument is used with kits other than QIAGEN Kits, it is the user’s responsibility to validate the performance of such product combination for any particular application.

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

특징

  • 사용하기 쉬운 새로운 형태의 미리 용액을 채운 reagent cartridge 형태
  • Run당 1에서96개 샘플까지 원하는 만큼 처리가능
  • Large sample volumes으로 high yields와 sensitivity 획득
  • 혁신적인 design을 통한 안전하고 진보된 실험 과정을 제공함
  • 가장 최신의 service와 support를 위한 QIAGEN Device Management

제품 세부 정보

With a dedicated range of QIAsymphony Kits, the QIAsymphony SP enables sample preparation of DNA, RNA, bacterial and viral nucleic acids, and 6xHis-tagged protein from a wide range of starting materials. The QIAsymphony AS extends the capabilities of the QIAsymphony SP by integrating automated PCR assay setup, which, in combination with the Rotor-Gene Q and QIAGEN real-time and end-point PCR kits, enables you to complete your automated PCR workflow and maximize your efficiency.

원리

The QIAsymphony SP can save you time by processing 1–96 samples — in batches of 24 — with sample volumes up to 2 ml. A dedicated range of QIAsymphony Kits increase laboratory efficiency since just a few kits in combination with optimized protocols cover an extensive range of starting materials and applications. QIAsymphony technology combines the speed and efficiency of silica- or Ni-NTA-based purification with the convenient handling of magnetic particles.

Dedicated QIAsymphony Kits for a wide range of starting materials
Kits Starting material and amount
QIAsymphony DNA Kit Purification of DNA from up to 1000 µl human whole blood, 400 µl buffy coat, 50 mg tissue (including FFPE tissue), or 1 x 107 cells, and purification of viral nucleic acids from blood
QIAsymphony DSP DNA Kit Purification of DNA from up to 1000 µl human whole blood, 400 µl buffy coat, tissue (including FFPE tissue), bacterial and cell cultures, and purification of viral nucleic acids from blood for in vitro diagnostic use
QIAsymphony DNA Investigator Kit Purification of reference and casework samples for human identity testing and forensics
QIAsymphony DSP Virus/Pathogen Kit  Purification of viral nucleic acids from plasma, serum, and CSF, and viral nucleic acids and bacterial DNA from respiratory and urogenital samples for in vitro diagnostic use
QIAsymphony DSP AXpH DNA Kit Purification of DNA from liquid-based cytology samples using AXpH technology, for in vitro diagnostic use
QIAsymphony RNA Kit Purification of total RNA and miRNA from up to 50 mg tissue (including FFPE tissue) or 1 x 107 cells
QIAsymphony PAXgene Blood RNA Kit* Purification of intracellular RNA (including miRNA) from 2.5 ml human whole blood collected in PAXgene Blood RNA Tubes
QIAsymphony Ni-NTA Native Kit Purification of 6xHis-tagged native proteins from up to 5 ml E. coli or up to 2.5 x 107 eukaryotic cells
QIAsymphony Ni-NTA Denaturing Kit Purification of 6xHis-tagged denatured proteins from up to 5 ml E. coli or up to 2.5 x 107 eukaryotic cells
QIAsymphony mericon Bacteria Kit Purification of bacterial DNA from 500 μl enrichment culture
QIAsymphony Certal Kits Purification of residual host cell DNA and viral NA from bioprocess purification buffer, cell culture supernatant samples, and vaccine preparations
* Up to 72 samples can be processed per run.
  

Extending the QIAsymphony SP with the QIAsymphony AS results in a fully integrated system that can automate complete workflows. Manual pipetting steps prone to human error are eliminated, making this system ideal for laboratories that perform complex PCR assays on a day-to-day basis. The QIAsymphony AS provides active cooling of reagents, eluates, and assays, enabling safe and reproducible assay setup. The QIAsymphony AS enables setup of multiple assays per run or sample and supports artus products and QIAGEN PCR and RT-PCR kits. A customization service is available for in-house assays.

With innovative design features, the QIAsymphony SP/AS instruments deliver exceptional process safety and standardization. Tip guards minimize the risk of cross-contamination and built-in UV lamps provide effective worktable decontamination. Bar code reading of samples and reagents enables full sample tracking throughout the entire purification and assay setup procedure. Chronological electronic documentation of results is provided, including information about sample IDs, their positions, and the lot number and expiry date of sample preparation and PCR reagents. Multi-level user management provides a record of which user was responsible for sample processing. Electronic result files can be automatically printed via a networked printer, or downloaded using a USB stick for archiving purposes.

The QIAsymphony Cabinet SP/AS (see figure " QIAsymphony Cabinet SP/AS") is specifically designed for correct positioning of the QIAsymphony SP/AS instruments. The QIAsymphony Cabinet SP/AS comprises two separate parts: one for the QIAsymphony SP and one for the QIAsymphony AS. If you have QIAsymphony SP and QIAsymphony AS instruments, you need both cabinet parts, which are then positioned side by side. If you just have a QIAsymphony SP instrument, only the QIAsymphony Cabinet SP is required. The QIAsymphony Cabinet SP and the QIAsymphony Cabinet AS each contain a waste compartment into which used tips from the worktable can be ejected.

 

그림 참조

절차

The QIAsymphony SP is ready-to-run and requires only minimal installation. Laboratories already operating a QIAsymphony SP can easily upgrade their system onsite with a QIAsymphony AS module. The QIAsymphony AS directly interfaces with the QIAsymphony SP. To reduce manual handling steps and minimize the risk of sample contamination, samples processed on the QIAsymphony SP can be transferred automatically to the QIAsymphony AS (integrated operation). For extra flexibility, the QIAsymphony SP and AS can also be operated independently. Samples that have been processed earlier in the day, or that have been processed on a different QIAsymphony SP, can be manually transferred to the QIAsymphony AS (see figure " QIAsymphony workflows").

Sample preparation and assay setup runs are defined using the touchscreen. Simply load drawers with the required samples, reagents, and consumables. When each drawer is closed, a detailed inventory scan is performed. This ensures that the worktable is correctly set up for the selected protocols. After sample preparation, either remove purified nucleic acids/proteins from the eluate drawer or automatically transfer eluates to the QIAsymphony AS via the transfer module for assay setup. After assay setup, assays can be transferred directly to a real-time PCR cycler for analysis.

The sample input drawer accommodates a wide range of sample input formats to suit varying workflows and sample preparation requirements. Bar code–labeled primary and secondary sample tubes (diameter 10–16.9 mm), microtiter plates, and blocks are supported. Continuous loading in batches of up to 24 samples plus internal controls, and the option to assign different protocols to each batch, delivers increased efficiency and walkaway time. The QIAsymphony AS enables setup of single or multiple PCRs per run or sample, splitting of eluates for panel testing, and active cooling of eluates, reagents, and PCRs. A choice of output adapters enables use of different real-time PCR cyclers (e.g., Rotor-Gene Q, 96-well cyclers, 32-capillary cyclers). To use the Rotor-Gene Q for detection, simply set up your PCRs in Strip Tubes or Rotor-Discs.

QIAsymphony Kits are safe and exceptionally easy to use. Ready-to-run, bar code-labeled reagent cartridges are prefilled with all reagents required for the purification procedure, including accessory enzymes (see figure " Prefilled, sealed reagent cartridges"). Worktable setup is rapid and saves you valuable time. Simply place up to 2 reagent cartridges in the QIAsymphony drawer. The reagent cartridges can be from the same or different kits, enabling different purification procedures to be performed within the same run of 96 samples. Reagent cartridges are automatically opened by the instrument, and reagent volumes only for the selected number of samples are used, giving you complete cost control.

그림 참조

응용 분야

The QIAsymphony SP/AS instruments are suitable for laboratories performing applications, such as:

  • Molecular diagnostics and biomedical research
  • Human identity testing
  • Veterinary applications
  • Biosecurity research
  • Life science applications, such as genomics and proteomics

소프트웨어

QIAsymphony operating software guides the user step-by-step through setting up a sample preparation or assay setup run, with options to select and adapt standardized protocols. Required volumes of buffers, reagents, master mix, and controls are automatically calculated, and the user is informed of the number and type of consumables to be loaded. Transfer of sample loading information from the QIAsymphony SP to the QIAsymphony AS is convenient and reduces the number of steps required for assay definition.

The QIAsymphony SP/AS instruments provide standardized communication interfaces. Work lists and rack files can be imported to the instruments, enabling automatic run definition before samples are received in the laboratory. After assay setup, sample lists can be exported to selected real-time PCR cyclers. This bi-directional data exchange allows integration of QIAsymphony SP/AS instruments into laboratory information management systems (LIMS).

서비스

Have your throughput demands increased? Do you want to expand your application range or further streamline workflows? Do you need to manage more complex samples? Do you need improved connectivity?

If the answer to any of these questions is yes, then QIAGEN’s trade-in/trade-up program is just right for you!

QIAGEN makes it easy to keep up to speed with the latest automation and sample processing technologies. Simply exchange an old instrument for a new one. Improve your efficiency by trading in a competitor instrument or trading up with an older QIAGEN instrument.

Learn more about trade-in/trade-up opportunities.

지원되는 데이터 및 수치

Specifications

FeaturesSpecifications
Power100–240 V AC, 50–60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages
Input volumeQIAsymphony SP — minimum input volume: 200 µl (application dependent)
Operating temperature15–32°C
Pollution level2
Place of operationFor indoor use only
Elution volumeQIAsymphony SP — 30–500 µl (application dependent)
Kits or Application Packs designed for this instrumentQIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits
Overvoltage categoryII
HumidityRelative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C
Instrument dimensionsQIAsymphony SP, 128 x 103 x 73 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm
ProcessingAutomated
Protocols/main application on this instrumentQIAsymphony SP — Purification of DNA, RNA, and bacterial and viral nucleic acids from a wide range of starting materials; QIAsymphony AS — PCR setup.
Storage temperature5–40°C in manufacturer's package
TechnologyQIAsymphony SP — QIAGEN magnetic-particles chemistry
Transportation temperature–25 to 70°C in manufacturer's package
WeightQIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg
AltitudeUp to 2000 m (6500 ft)

서비스 계획

QIAsymphony SP/AS, Premium Agreement

Cat. No. / ID:   9242508

On-site QIAsymphony SP/AS instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period..

QIAsymphony SP, Premium Agreement

Cat. No. / ID:   9241208

On-site QIAsymphony SP instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period.

QIAsymphony AS, Premium Agreement

Cat. No. / ID:   9244820

On-site QIAsymphony AS instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period.

QIAsymphony SP/AS, Full Agreement

Cat. No. / ID:   9242507

On-site QIAsymphony SP/AS instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

QIAsymphony SP, Full Agreement

Cat. No. / ID:   9241207

On-site QIAsymphony SP instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

QIAsymphony AS, Full Agreement

Cat. No. / ID:   9244819

On-site QIAsymphony AS instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

QIAsymphony SP, Preventive Subscription

Cat. No. / ID:   9243545A

One on-site Preventive Maintenance or Inspection Service visit for the QIAsymphony SP, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

QIAsymphony SPAS Preventive Subscription

Cat. No. / ID:   9243546A

One on-site Preventive Maintenance or Inspection Service visit for the QIAsymphony SP/AS, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

QIAsymphony AS, Preventive Subscription

Cat. No. / ID:   9244817A

One on-site Preventive Maintenance or Inspection Service visit for the QIAsymphony AS, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

리소스

Application/Protocol Documents (27)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
Supporting Software and Tools (2)
For QIAsymphony software version 5.0.4
Work List Tool
SOFTWARE (1MB)
For QIAsymphony Software version 5.0
Protocol Files (8)
For use with the QIAsymphony SP/AS instruments (software version 5.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 5.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Instrument User Manuals (5)
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with software version 5.0
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
Safety Data Sheets (1)
Instrument Technical Documents (10)
QIAsymphony Cabinet SP/AS documents
Differences between QIAsymphony software versions
For use with QIAsymphony SP/AS instruments (software version 5.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
QIAsymphony Cabinet SP/AS document
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Software document for QIAsymphony software version 4.0.1
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Labware Files and Documents (2)
For use with software version 5.0 or higher
Technical Information and Important Notes (1)
Certificates of Analysis (1)

FAQ

What RNA elution volumes are available with the QIAsymphony RNA Kit?

RNA processed on the QIAsymphony SP with the QIAsymphony RNA Kit can be eluted in 200, 100, or 50 µl.

Elution in smaller volumes will provide higher concentration, but lower overall yield. Total RNA yield with elution in 50 µl will be about 20% lower compared to elution in 100 µl.

 

FAQ ID -1943
What are the starting volumes of homogenate for RNA extraction on the QIAsymphony SP?

Using the Standard protocol for RNA extraction on the QIAsymphony SP, up to 400 µl of lysate can be processed while the Large-Volume protocol allows up to 800 µl of homogenate.

 

 

 

 

FAQ ID -1939
The QIAsymphony RNA kit uses RLT plus as lysis buffer. Can samples lysed in RLT and then stored in the freezer be used on the QIAsymphony?

The RLT buffer is more viscous than the RLT plus buffer. Extraction will work fine, but there may be some magnetic bead carryover to the eluate.

FAQ ID - 3533
Can DNA yields be increased by prolonging incubation with proteinase K in Buffer ATL?

For most sample types, incubating longer than specified in the pretreatment protocol for the QIAsymphony DNA Investigator Kit does not increase yields. However, lysates can be incubated overnight without negatively affecting the quality of the extracted DNA.

 

FAQ ID -2032
Is there a charge for user training on the QIAsymphony SP System?

No. Sample handling, software, and introduction to maintenance for the QIAsymphony SP System are included in the installation training and are covered by the installation fee.

 

 

FAQ ID -1900
Are there any specific cleaning solutions recommended for the QIAsymphony SP?

The following disinfectants and detergents are recommended for cleaning the QIAsymphony SP:

  • Mikrozid® Tissues (Schülke & Mayr GmbH) — 150 tissues with 235 g agent (consists of 24g (94%) ethanol and 35g 1-propanol per 100g agent)
  • Mikrozid Liquid (Schülke & Mayr GmbH) — ethanol-based disinfectant for spraying onto surfaces (consists of 25 g ethanol and 35 g 1-propanol per 100 g agent solution)
  • RBS®-35 Detergent Concentrate (Pierce Chemical Co.) — anionic and nonionic surfactant based detergent for cleaning the touch screen and worktable door.
  • RNaseZap® (Ambion) — for complete removal of RNase contamination from glass and plastic surfaces
  • 0.1 M NaOH — for cleaning the worktable and racks to remove RNase contamination (alternative to RNaseZap)

Europe

  • Lysetol® AF (Gigsept® Instru AF) (Schülke & Mayr GmbH) — disinfectant for submerging worktable items (consists of 14 g cocospropylene-diamine-guanidine diacetate, 35 g phenoxypropanols, and 2.5 g benzalkonium chloride per 100 g Lysetol AF, with anticorrosion components, fragrance, and 15-30% nonionic surfactants

USA

  • DECON-QUAT® 100 (Veltek Associates, Inc.) — quaternary ammonium salt based disinfectant concentrate for submerging worktable items (contains 5% alkyldimethylbenzylammonium chloride and 5% alkyldimethylethylbenzylammonium chloride)

Note: If you want to use disinfectants different from those recommended, ensure that their compositions are similar to those described above.

FAQ ID -1913
Can I program my own protocols for the QIAsymphony SP?

No. Modified QIAGEN protocols or custom protocols for QIAsymphony SP can be developed to meet your specific requirements and purchased from QIAGEN.

 

 

 

FAQ ID -1904
Does an internal control have to be included for each QIAsymphony Virus/Bacteria protocol run?

No. The use of internal controls with the QIAsymphony Virus/Bacteria Kits is not mandatory. When using internal controls, they are added to the carrier RNA mixture (total volume of the mixture must be 120 µl).

 

FAQ ID -2040
Can uneven sample numbers be processed on the QIAsymphony SP module?

Yes. Any number of samples between 1 and 96 can be processed on the QIAsymphony SP.

 

 

FAQ ID -1906
There is no barcode on the QIAsymphony cooling adapter, and the instrument asks for one. What do you suggest I do?

The barcode on the adapter at the cooling elution position is read by default. This can be changed in the configuration settings which are available from the tools menu if you have logged in as Supervisor. The option is on the tab Process SP1 and is called ”On which elution slots should the bar codes be scanned”. To disable the barcode reading, put the setting to ”none”.

FAQ ID - 3532
Can the QIAsymphony RNA Kit be used to purify RNA from blood?

For purification of RNA from blood on the QIAsymphony SP, we recommend using the QIAsymphony PAXgene RNA Kit, since it includes stabilization of gene expression profiles.

 

 

FAQ ID -1945
Why do I have to use an ACS (Assay Control Set)?
The ACS specifies the combination of a protocol and a predefined carrier RNA–internal control mixture. The user can define an internal control mixture using the QIAsymphony Management Console. A predefined internal control-carrier RNA-Buffer AVE mixture can be automatically identified by the instrument using a bar code label or it can be chosen manually.
FAQ ID -2933
Which QIAsymphony Virus/Bacteria Kit size should be used for each protocol?

The QIAsymphony Virus/Bacteria Mini Kit is used with the 'Cellfree_200' and 'Complex_200' protocols.

The QIAsymphony Virus/Bacteria Midi Kit is used with the 'Cellfree_500’, 'Cellfree_1000', ‘Complex_400’ and 'Complex_800' protocols.

FAQ ID -2038
What is the part number for O-rings for QIAsymphony SP and AS instruments? How often should the O-rings be replaced?

Part number for O-rings for pipetting channels of QIAsymphony SP and AS instruments is 9019168. There are 32 O-rings included in one bag.

You will also require the tool to change the O-rings. Part number for this tool is: 9019164. This tool set includes one bag of 32 O-rings.

We recommend replacing O-rings on all pipetting channels, once a month.

              

FAQ ID -3055
Can I change the language on my QIAsymphony SP system?

Yes, this is possible from software version 4.1 on. Please ask Technical Service for an update. The respective language package can be found on https://www.qiagen.com/de/resources/resourcedetail?id=7d184844-365d-43bf-95f4-0031cd5a4b8e&lang=en

FAQ ID - 3595
What sample types can be processed using the tissue protocols and the QIAsymphony DSP DNA Mini Kit?
Tissue and FFPE tissue can be processed using the tissue protocols and the QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP.
FAQ ID -2925
Can solid samples be processed with the QIAsymphony DNA Investigator Kit on the instrument?

No. All solid materials (e.g., swabs, blood card punches, chewing gum) must be removed completely from the lysate before performing automated extraction on the
QIAsymphony SP. The QIAshredder can be used to increase sample recovery from some solid materials. For more information, see the corresponding pretreatment protocol.

 

FAQ ID -2027
Is sample pretreatment required for purifying RNA on the QIAsymphony SP?

For purification of RNA on the QIAsymphony SP, tissue samples require mechanical disruption and homogenization in the supplied lysis buffer (Buffer RLT Plus), e.g., by using the TissueLyser or TissueRuptor. Cultured cells should be lysed by vortexing in the lysis buffer contained in the kit.

 

FAQ ID -1938
How can I create a report/logfile on my QIAsymphony SP system?

Please navigate to Tools/Instrument Report/Create + Save to USB.

FAQ ID - 3594
Does carrier RNA have to be added using the QIAsymphony Virus Blood 200 Protocol?

No. We do not recommend use of carrier RNA with the QIAsymphony Virus Blood 200 Protocol.

 

FAQ ID -2163
How does magnetic-particle carry-over in QIAsymphony eluates need to be handled?

In general, magnetic particles are not carried over into QIAsymphony eluates. However, if high amounts of genomic DNA are purified (large number of white blood cells in the sample) magnetic-particle carryover may be observed. If carryover does occur, magnetic particles in eluates will not affect most downstream applications. If magnetic particles need to be removed before performing downstream applications, tubes or plates containing eluates should first be placed in a suitable magnet and the eluates transferred to a clean tube.

 

FAQ ID -2166
How much starting material can be used with the QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP?

Tissue: If no information about the expected yield is available, we recommend starting with 25 mg sample material. Depending on the yield obtained, the sample size can be increased in subsequent preparations to a maximum of 50 mg.

FFPE: Up to 4 sections, each with a thickness of up to 10 µm, or 8 sections with a thickness of up to 5 µm and a surface area of up to 250 mm2, can be combined in one preparation.

FAQ ID -2927
How should DNA isolated on the QIAsymphony be stored?

Eluates obtained on the QIAsymphony SP can be stored at 2–8°C for 3 days before use in downstream applications and should be placed at –20°C or –80°C for long-term storage.

 

 

FAQ ID -2165
What sample types can be processed using the QIAsymphony Virus/Bacteria protocols?

Plasma, serum, and CSF samples can be processed using the Virus Cellfree protocols of the QIAsymphony Virus/Bacteria Kits. Respiratory samples (sputum, BAL, aspirates, dried swabs, transport media), and urogenital samples (urine, urogenital swabs, transport media) can be processed using the Pathogen Complex protocols.

 

FAQ ID -2036
Do tissue samples require pretreatment before loading onto the QIAsymphony SP for DNA extraction?
Yes. Samples have to be completely lysed and homogenized prior to automated processing on the QIAsymphony SP platform using the QIAsymphony DSP DNA Mini Kit. Tissue samples are lysed by proteinase K digestion. FFPE tissue samples are deparaffinized with Deparaffinization Solution or xylene/ethanol and lysed by proteinase K digestion. Insoluble material is pelleted by centrifugation. Lysates are placed on the QIAsymphony SP for purification of DNA (see protocol sheets for details).
FAQ ID -2926
What are the expected DNA yields from tissue processed on the QIAsymphony SP?

DNA yields strongly depend on the type and source of the tissue processed on the QIAsymphony SP. Approximately 70–80 µg DNA can be isolated from 25 mg of spleen, 40–50 µg from 25 mg liver, and 10–15 µg from 50 mg muscle.

 

FAQ ID -1919
What sample input volumes can be used on the QIAsymphony SP?
200–1000 µl sample volumes can be processed on the QIAsymphony Sample Prep Module.
FAQ ID -1907
How much starting material can be used with the QIAsymphony DNA Mini Kit on the QIAsymphony SP?

The maximum amount of tissue that can be processed on the QIAsymphony SP using QIAsymphony DNA Mini Kit is 50 mg, and the maximum number of cultured cells is 1 x 107.

See details for upper limits of various starting materials in the table below:

 

Sample type Sample amount Protocol
Heart 25 mg Tissue Standard
Spleen 25 mg Tissue High Content
Lung 25 mg Tissue Standard
Liver 25 mg Tissue High Content
Kidney 25 mg Tissue Standard
Muscle 50 mg Tissue Standard
Mouse tail 0.8 cm Tissue Standard
Jurkat Cells 2 x 10e6 Tissue Standard
Jurkat Cells 1 x 10e7 Tissue High Content

FAQ ID -1917
How can I decontaminate my QIAsymphony SP / AS system?

The QIAsymphony system has an integrated UV lamp. UV decontamination should be performed daily. It helps to reduce possible pathogen contamination of the QIAsymphony SP/AS worktables. The efficiency of inactivation has to be determined for each specific organism and depends, for example, on layer thickness and sample type. QIAGEN cannot guarantee complete eradication of specific pathogens.

FAQ ID - 3714
How many samples can be processed with the QIAsymphony DNA Mini Kit and the Virus Blood 200 protocol?

A total of 192 samples can be processed with one QIAsymphony DNA Mini Kit and the Virus Blood 200 protocol (96 samples per reagent cartridge).

 

 

 

FAQ ID -2159
Can protocol runs on the QIAsymphony SP be interrupted and resumed?

QIAGEN protocols on the QIAsymphony SP can be stopped if there is an emergency by pressing "Pause". To confirm that you want to stop the protocol run, press "Stop". To cancel the stop protocol command, press "Continue".

Note: If a protocol run is stopped, the run cannot be restarted. Samples must be processed manually. For more information, refer to the QIAsymphony User Manual.

 

FAQ ID -1912
Is the QIAsymphony RNA Kit compatible with stabilized samples?

Yes, the QIAsymphony RNA Kit is compatible with stabilized samples. We recommend stabilizing tissue samples with RNAprotect Tissue Reagent or AllProtect Tissue Reagent, or by flash-freezing. Cultured cells can be lysed directly in cell culture dishes, or after pelleting. Alternatively, cells can be stabilized using RNAprotect Cell Reagent.


FAQ ID -1944
What sample types can be processed using the QIAsymphony DSP Virus/Pathogen protocols?
Plasma, serum, and CSF samples can be processed using the QIAsymphony DSP Virus/Pathogen cellfree protocols. Respiratory samples (sputum, BAL, aspirates, dried swabs, transport media), and urogenital samples (urine, urogenital swabs, transport media) can be processed using the pathogen complex protocols.
FAQ ID -2928
What sample volumes can be used with the Virus Blood 200 Protocol on the QIAsymphony?

Sample volumes of 200 µl can be processed with the Virus Blood 200 Protocol using the QIAsymphony DNA Mini Kit.

 

 

FAQ ID -2156
What sample volumes can be used with the tissue HC and LC protocols on the QIAsymphony SP?
After pretreatment, 220 µl of the lysates must be transferred to the QIAsymphony SP to ensure that 200 µl of sample is processed.
FAQ ID -2992
What are the recommended lysis times for tissue samples on the QIAsymphony SP?
Lysis time varies depending on the tissue type processed. For recommended lysis times refer to the tissue protocol sheets. If lysis is incomplete after recommended lysis time, as indicated by the presence of insoluble material or highly viscous lysates, lysis time can be prolonged or insoluble material can be removed by centrifugation. Overnight lysis is possible and does not affect the preparation.
FAQ ID -2993
Do samples require pretreatment before loading onto the QIAsymphony SP for DNA extraction?

Yes. Samples have to be completely lysed and homogenized prior to automated processing on the QIAsymphony SP platform using QIAsymphony DNA Kits.

Samples are lysed by Proteinase K digestion in lysis buffers optimized for tissue, cultured cells, and bacteria, respectively. For lysis of gram-positive bacteria, lysozyme is used in addition to Proteinase K. Lysed samples are homogenized by pipetting up and down, and insoluble material is removed by centrifugation (see the QIAsymphony DNA Handbook for details).

 

FAQ ID -1916
How should samples be stored before purification using the Virus Blood 200 Protocol on the QIAsymphony?

Samples should be processed on the QIAsymphony within 24 hours of collection. Samples should be transported and stored at 2–25°C.

 

 

 

FAQ ID -2157
Should sample lysate volumes be exactly 200 µL, 500 µL, or 1000 µL when loaded on the QIAsymphony SP?

No. The specified lysate volumes are optimal for QIAsymphony DNA Investigator Kit protocols. Lower volumes (150 µL,400 µL, 900 µL, respectively) can be used.

However, to maximize yields, we recommend transferring as much of the lysate as possible.
The QIAshredder can be used to increase recovery from some sample types. For more information, see the corresponding pretreatment protocol.

 

FAQ ID -2031
What are the dimensions and weight of the QIAsymphony SP System?

The QIAsymphony SP instrument has the following weight and dimensions:

  • Weight: 178 kg (392.4 lb.); 220 kg (485 lb.) with packaging
  • Width: 130 cm (51.2 in.)
  • Depth: 75 cm (29.5 in.); 125 cm (49.2 in.) with drawer open
  • Height (door closed): 103 cm (40.6 in.)
  • Height (door open): 163 cm (64.2 in.)
FAQ ID -1901
Can the QIAsymphony SP Module be connected to a laboratory information management system (LIMS)?

Yes, QIAsymphony SP can be connected to a lab information management system. Result files can be exported in html format. At a later date, users will be able to import sample worklists to the QIAsymphony SP.

 

FAQ ID -1909
Which types and amounts of sample material can be processed for RNA extraction on the QIAsymphony SP?

The QIAsymphony RNA Kit enables purification of RNA from cultured cells and easy-to-lyse tissues, such as kidney, liver, and spleen on the QIAsymphony SP. A large-volume protocol is available that enables processing of larger sample amounts.

  • Cultured cells: up to 3x106 cells (standard protocol); up to 1x107 (large volume protocol)
  • Tissues: up to 20 mg of most tissues (standard protocol); up to 50 mg (large-volume protocol)

For particularly DNA-rich tissues, such as spleen or thymus, we recommend either using no more than half the maximum amount, or using DNase at a higher concentration (see the QIAsymphony RNA Handbook; additional DNase required).

FAQ ID -1937
What sample volumes can be processed with the QIAsymphony Virus/Bacteria Kits?

Sample volumes that can be processed with the QIAsymphony Virus/Bacteria Kits depend on the protocol:

  • 'Cellfree_200' and 'Complex_200':  200 µl
  • 'Complex_800':                            800 µl
  • 'Cellfree_1000':                           1000 µl

 

FAQ ID -2037
Which sample types can be processed using the QIAsymphony Virus Blood 200 protocol?

Human whole blood samples treated with EDTA or citrate can be processed using the QIAsymphony Virus Blood 200 protocol with the QIAsymphony DNA Mini Kit. We do not recommend using heparin-treated blood samples.

 

 

 

FAQ ID -2154
Will mitochondrial DNA also be isolated using the DNA Tissue protocols on the QIAsymphony SP?

Yes. The DNA Tissue protocols on the QIAsymphony SP purify genomic and mitochondrial DNA.

 

 

 

 

FAQ ID -1921
How can I determine if a tube is suitable for clot detection on QIAsymphony?

You can find this information in the respective labware list. All tubes which require an insert in the sample input carrier or plates are not suitable.

FAQ ID - 3590
Is mitochondrial DNA isolated with the QIAsymphony DNA Investigator Kit on the QIAsymphony SP?

Yes. QIAsymphony DNA Investigator Kit protocols purify both genomic and mitochondrial DNA.

 

 

 

FAQ ID -2030
How long can homogenates remain on the QIAsymphony SP without risk of RNA degradation?

Strongly denaturing conditions in the lysis buffer (Buffer RLT Plus) of the QIAsymphony RNA Kit keep RNases in an inactive state. Keeping homogenates on the QIAsymphony instrument at room temperature (20-25°C) for over 6 hours does not impair RNA integrity.

 

FAQ ID -1941
Which elution volumes can be selected using the QIAsymphony Virus Blood 200 protocol?

Final elution volumes of 60 µl, 85 µl, 110 µl, or 165 µl can be selected using the QIAsymphony Virus Blood 200 protocol. Please note that the initial elution volumes are 95 µl, 120 µl, 145 µl, or 200 µl. When calculating the amount of internal control(s) as well as the titer of the processed sample, it is necessary to take into consideration the initial volume of elution buffer that is used for each sample.

 

FAQ ID -2160
Is it possible to modify QIAsymphony protocols?

No. Protocols on the QIAsymphony SP cannot be modified by users. However, protocols allow elution volumes to be selected within a predefined range. Customized protocols for QIAsymphony SP will be available on request.

 

FAQ ID -1903
Which barcodes on sample tubes are accepted by the QIAsymphony SP?

Code 39, code 128 and subtypes, Codabar

FAQ ID - 3598
What sample types should be processed with the High Content (HC) protocol for DNA extraction on the QIAsymphony SP?

The High Content protocol for DNA extractions on the QIAsymphony SP is optimized for samples with an expected DNA yield of more than 30 µg. Up to 90 µg DNA can be purified from tissues with high cell densities (e.g., spleen) or large numbers of cultured cells.

 

FAQ ID -1918
Is clot detection possible on the QIAsymphony?
Yes, clot detection is possible on the QIAsymphony.
FAQ - ID 3588
How does QIAsymphony SP keep cellular samples in suspension prior to pipetting so that samples do not settle?
Samples are mixed before pipetting by the QIAsymphony SP Module.
FAQ ID -1905
Does the QIAsymphony SP system generate run reports and/or log files?

Yes. At the end of each protocol run on the QIAsymphony SP, a report file is generated that contains important information such as number of samples, liquid volumes measured during the load check, and run time. A log file is also generated that contains information about instrument actions, such as movement of the robotic arm.

 

 

FAQ ID -1911
What is the range of elution volumes on the QIAsymphony SP?

Depending on the application, elution volumes on the QIAsymphony SP range from 30 µl to 500 µl.

 

 

 

FAQ ID -1908
What kind of samples should be processed using the large-volume protocol with the QIAsymphony DNA Investigator Kit?

The large-volume protocol of the QIAsymphony DNA Investigator Kit is intended for samples that can not be submerged completely during lysis in volumes less than 1 ml, as well as samples that are very absorbent.

 

FAQ ID -2034
What are the expected yields of total RNA isolated with the QIAsymphony SP?

Please see expected yields of total RNA isolated with the QIAsymphony RNA Kit on the QIAsymphony SP in the table below:

 

Sample type Sample amount Typical RNA yield (µg)*

Cultured Cells

   
HeLa, Jurkat 1 x 10e6 cells 15

Rat tissues

   
Kidney 10 mg 10-25
Liver 10 mg 20-50
Lung 10 mg 5-10
Spleen 10 mg 25-35

*RNA yields strongly depend on the type and quality of the sample material.

FAQ ID -1942
What sample types can be processed using the tissue protocols for DNA extraction on the QIAsymphony SP?

Various types of tissue, cultured cells, and bacterial pellets can be processed using the tissue protocols for the QIAsymphony DNA Kits on the QIAsymphony SP.

 

 

 

 

FAQ ID -1915
Do QIAsymphony Virus/Bacteria samples require pretreatment before they are loaded onto the instrument?

Pre-treatment of samples used with the QIAsymphony Virus/Bacteria Kits can improve nucleic acid extraction for some sample types. Viscous samples (e.g., sputum, respiratory aspirates) might require liquefaction to enable pipetting. Pretreatment protocols are provided in the QIAsymphony Virus/Bacteria Handbook.

 

FAQ ID -2039
Is RNA co-purified with DNA using QIAsymphony DNA Tissue protocols?

Yes. Magnetic particles used in the QIAsymphony SP System will bind RNA and total DNA. If isolation of RNA-free DNA is required, RNase A must be added to the lysate before isolation of DNA.

 

FAQ ID -1920
Are QR codes recognized by QIAsymphony?
No, currently only barcodes can be used to label samples for QIAsymphony. We have no plans to introduce QR code recognition any time soon.
FAQ ID - 3625
What is the thermal output for a QIAsymphony SP and AS instrument?

Power consumption of a QIAsymphony SP instrument is 800 VA. Therefore, the approximate thermal output is 2729 BTU/h.

If the QIAsymphony SP is connected to a QIAsymphony AS, then the power consumption is 1400 VA. The thermal output is ~4777 BTU/h.

 

FAQ ID -3057
What is the maximum DNA yield from forensic samples processed with the QIAsymphony SP?

QIAsymphony DNA Investigator Kit protocols are optimized for maximum sensitivity in extraction of typical forensic-casework and reference sample types, which usually have low DNA content. Due to optimized bead capacity, maximum DNA yields are approximately 3 µg.

 

FAQ ID -2028
In which tubes is clot detection possible on QIAsymphony?
Only tubes with a diameter < 15 mm can be used for clot detection on the QIAsymphony.

FAQ ID - 3589

What sample tubes can I use on my QIAsymphony SP system?

Please navigate to the Product Page of the QIAsymphony Kit you are using; for example, the QIAsymphony RNA Kit, Cat No./ID: 931636.  Refer to the resources tab and download the labware document. The labware document will list the sample tubes that have been tested for your application. Please contact Technical Service if you wish to use sample tubes not listed in the labware document.

FAQ ID - 3713
What sample types should be processed with the low content (LC) and high content (HC) protocols for DNA extraction on the QIAsymphony SP?
Tissues will give increased DNA yields when processed with the high content protocol, but the low content protocol in combination with a small elution volume (50µl) may be used if high DNA concentration is required. For FFPE tissue we recommend using the low content protocol.
FAQ ID -2989
Do all QIAsymphony DNA Investigator protocols use carrier RNA?

No. Carrier RNA is only used in casework protocols for the QIAsymphony DNA Investigator Kit to enable efficient extraction of minute quantities of DNA. Carrier RNA is not used in reference protocols.

 

FAQ ID -2033
Does an internal control have to be used with the QIAsymphony Virus Blood 200 Protocol?

No. The use of internal controls is not mandatory for use with the QIAsymphony Virus Blood 200 Protocol. If an internal control is not required, Buffer ATE without internal control is added to the samples. Buffer ATE must be placed in slot A of the sample drawer.

 

FAQ ID -2162
What are the expected DNA yields from tissue processed on the QIAsymphony SP?
DNA yields strongly depend on the type and source of the tissue processed on the QIAsymphony SP. For FFPE tissue samples, the DNA yield depends highly on the fixation and processing of the tissue material. QIAsymphony magnetic particles copurify RNA and DNA if both are present in the sample. RNA may influence photometric analysis and may lead to overestimated nucleic acid yields. If RNA-free DNA is required, add RNase A in the step indicated in the respective pretreatment protocol (see protocol sheets for details).
FAQ ID -2990
How can the QIAsymphony SP system be decontaminated?
To decontaminate the QIAsymphony SP, refer to the QIAsymphony User Manual.
FAQ ID -1914
Why do casework-sample protocols for the QIAsymphony DNA Investigator Kit start with different lysate volumes (200 µl, 500 µl, or 1000 µl)?

To ensure performance with the QIAsymphony DNA Investigator Kit, lysis volumes have been optimized according to sample type. In general, large or absorbent samples require larger buffer volumes than small and non-absorbent samples.

 

FAQ ID -2035
What is elution Buffer ATE of the QIAsymphony DNA Investigator Kit?

Buffer ATE of the QIAsymphony DNA Investigator Kit is a low-EDTA elution buffer optimized for long-term storage of DNA as well as performance in sensitive downstream applications. Alternatively, casework protocols using water for elution are available.

 

Buffer ATE contains a small amount of the preservative sodium azide. If the eluate is measured for absorbance the spectrophotometer should be blanked with the buffer ATE as sodium azide absorbs strongly at 230 nm. 

 

FAQ ID -2029
How many samples can be processed per kit or per reagent cartridge for RNA purification on the QIAsymphony SP?

Each QIAsymphony RNA Kit enables preparation of up to 192 samples (96 per reagent cartridge) using the standard protocol on the QIAsymphony SP. If only the large-volume protocol is used, the number of samples that can be prepared per kit is reduced to 96 (48 per reagent cartridge). Any combination of standard and large-volume sample preparation can be performed.

 

FAQ ID -1940
Will mitochondrial DNA also be isolated using the DNA tissue protocols and QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP?
Yes. The DNA tissue protocols on the QIAsymphony SP purify genomic and mitochondrial DNA.
FAQ ID -2991
What is the target nucleic acid for the Virus Blood 200 Protocol on the QIAsymphony?

The target nucleic acid for the Virus Blood 200 Protocol on the QIAsymphony is viral DNA from released as well as cell-associated viruses, co-purified with genomic DNA from blood cells.

 

 

FAQ ID -2158