dPCR PanCancer Kits

For detection of multiple hallmark mutations in cancer-relevant genes using the QIAcuity digital PCR instruments

S_1084_5_GEN_V2

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

dPCR PanCancer Kit BRAF V600 FAM (200)

Cat. No. / ID:   250284

200 x 40 µl reactions: Includes 20x BRAF V600 FAM assay, 20x AP3B1 HEX reference assay, water and 4x QIAcuity Master Mix for screening 8 BRAF V600 mutations using the QIAcuity
¥289,000
Log in To see your account pricing.
Kit
BRAF V600
EGFR ex19del
dPCR PanCancer Kits are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Parallel detection of hallmark mutations with frequencies as low as 0.1% 
  • Reference assay quantifies genome copies and check for dPCR efficiency
  • Reference gene and hallmark mutations detected in a single run using two different dyes
  • Simple and fast dPCR protocol on the QIAcuity
  • Compatible with QIAGEN sample preparation kits and instruments 

Product Details

The dPCR PanCancer Kits have been designed for various cancer-relevant target genes. Using a single assay, the kits can detect multiple mutations or deletions in a target gene. The dPCR PanCancer Kit BRAF V600 FAM can detect eight key mutations in BRAF V600, and the dPCR PanCancer Kit EGFRex19del FAM can detect 23 deletions in exon 19 of the EGFR gene. 


Each dPCR PanCancer Kit consists of two boxes: one box with the specific PanCancer Assay with FAM-labeled gene-specific primers and a HEX-labeled reference gene to check for PCR efficiency, and the other with the QIAcuity Master Mix (see figure " dPCR PanCancer Kit concept"). The primers and probes come pre-mixed in the right concentrations. 


The assay is optimized for QIAcuity Nanoplate 26k 24-well, but other nanoplate formats are also possible. The easy-to-use dPCR workflow on the QIAcuity allows fast, precise and cost-efficient screening of your samples. 

 

See figures

Performance

High sensitivity in mutation detection


The dPCR PanCancer Kits have been developed to meet the need for precise and time-efficient screening of cancer samples in your research projects. The assays can detect multiple mutations in parallel, down to 0.1% mutation frequency, in various sample types used in cancer research.


Parallel detection of multiple hallmark mutations and reference gene 


The QIAcuity Nanoplate 26k 24-well allows the analysis of 24 samples in parallel. Each assay detects several cancer-relevant mutations in parallel within a specific target gene in a single channel. As the reference assay for AP3B1 comes with a different dye than the assay for the mutations, the readout can be done using two different channels on the QIAcuity but in the same reaction well, saving precious samples and allowing more samples to be run on one plate (see figures " Accurate detection of BRAF V600E mutations in DNA reference standard using the dPCR PanCancer Kit BRAF V600 FAM" and " Accurate detection of EGFR exon19 deletion in DNA reference standard using the dPCR PanCancer Kit EGFRex19del FAM).


Compatible with multiple sample types and sample preparation methods


The dPCR PanCancer Kits are compatible with QIAGEN sample collection devices, preparation kits and instruments, allowing you to meet diverse throughput, reproducibility and sensitivity needs. Whether you isolate your DNA manually using a QIAGEN kit, such as the QIAamp Circulating Nucleic Acid Kit for cfDNA, QIAamp DNA Blood Kits for blood DNA or QIAamp DNA FFPE Advanced Kit for FFPE DNA, or perform automated DNA isolation using the EZ2 Connect or QIAsymphony SP, the dPCR PanCancer Kits work with all of them. 

See figures

Principle

The dPCR PanCancer Kits – BRAF V600 FAM and EGFRex19del FAM – detect multiple hallmark mutations in the serine/threonine protein kinase B-Raf encoding gene BRAF and the epidermal growth factor receptor encoding gene EGFR, respectively.


The assays are designed for use with the QIAcuity Master Mix and the QIAcuity Digital PCR System. Each assay involves endpoint PCR amplification targeting specific genetic regions of the relevant cancer gene. The amplified product is detected using target-specific fluorescent hydrolysis probes, enhancing the assay's specificity.


Below is a detailed overview of the covered mutations with the unique COSMIC database v99 identifiers. Additionally, each dPCR PanCancer Kit incorporates a reference assay that quantifies the human single-copy gene AP3B1, providing a benchmark for determining genome copies in the sample. While the recommended setup involves a QIAcuity Nanoplate 26k 24-well, these assays are also compatible with other QIAcuity Nanoplate types, offering versatility in experimental configurations. You can also download a table with a summary of positive control templates for the BRAF and EGFR PanCancer Assays (see Resources section).


Learn the principle behind QIAcuity nanoplate-based digital PCR here.

 

Procedure

The dPCR PanCancer Kit protocol is simple and can be performed in any laboratory with the QIAcuity dPCR instrument. Following the instructions in the user manual and the Quick Start Protocol, the user prepares the reaction mix and pipettes the mix into the nanoplate. We recommend using the 26k nanoplate and keeping the software up to date. Isolated DNA is added to the ready-to-use QIAcuity Probe Master Mix and nuclease-free water. This mix is aliquoted into each well of the dPCR pre-plate, which contains pre-dispensed sets of primers and hydrolysis probes. The reaction mixtures are transferred from the pre-plate to the dPCR nanoplate wells, which are then sealed and transferred to the QIAcuity dPCR instrument (see figure " A simple and rapid plate-based workflow"). The partitioning, cycling and imaging steps are fully automated by the QIAcuity dPCR instrument following the preset parameters. Depending on the cycling protocol, the results of the dPCR run can be analyzed using the QIAcuity Software Suite in ~2 hours.

 

See figures

Applications

The dPCR PanCancer Kits are highly suited for detecting mutations or deletions in DNA isolated from blood, plasma, fresh tissue or FFPE, but other sample types are also possible. The assays are compatible with the QIAGEN workflow and have been validated via wet-lab testing (see figure " Detection of BRAF V600 mutations (A) and EGFR exon 19 deletions (B) in cfDNA extracted from blood plasma using the dPCR PanCancer Kit on the QIAcuity platform"). The results from manual and automated DNA extraction and subsequent dPCR analysis are shown. Data coherence with DNA extracted using different QIAGEN sample preparation methods is demonstrated.

See figures

Mutations covered with COSMIC IDs
Target gene and region Amino acid position Nucleotide change COSMIC ID
dPCR PanCancer Kit BRAF V600 FAM p.V600K c.1798_1799delinsAA COSV56057713
p.V600R c.1798_1799delinsAG COSV56058419
p.V600E c.1799_1800delinsAA COSV56059110
p.V600E c.1799T>A COSV56056643
p.V600D c.1799_1800delinsAT COSV56059623
p.V600G c.1799T>G COSV56080151
p.V600M c.1798G>A COSV56075762
p.V600R c.1798_1799delinsCG COSV56288520
dPCR PanCancer Kit EGFRex19del FAM  p.K745_E749del c.2233_2247del COSV51769442
p.E746_A750delinsIP c.2235_2248delinsAATTC COSV51817953
p.E746_A750del c.2235_2249del COSV51765119
p.E746_T751delinsIP c.2235_2251delinsAATTC COSV51782151
p.E746_T751delinsI c.2235_2252delinsAAT COSV51850034
p.E746_A750del c.2236_2250del COSV51765066
p.E746_T751delinsA c.2237_2251del COSV51769364
p.E746_T751delinsV c.2237_2252delinsT COSV51775936
p.E746_T751delinsVA c.2237_2253delinsTTGCT COSV51771891
p.E746_S752delinsV c.2237_2255delinsT COSV51765862
p.L747_A750delinsP c.2238_2248delinsGC COSV51782279
p.L747_T751delinsQ c.2238_2252delinsGCA COSV51863059
p.E746_S752delinsD c.2238_2255del COSV51772418
p.L747_E749del c.2239_2247del COSV51780076
p.L747_A750delinsP c.2239_2248delinsC COSV51765099
p.L747_T751delinsP c.2239_2251delinsC COSV51765856
p.L747_S752del c.2239_2256del COSV51767308
p.L747_S752delinsQ c.2239_2256delinsCAA COSV51778874
p.L747_P753delinsQ c.2239_2258delinsCA COSV51785746
p.L747_T751delinsS c.2240_2251del COSV51768180
p.L747_T751del c.2240_2254del COSV51766247
p.L747_A750delinsS c.2240_2248del COSV51810296
p.L747_P753delinsS c.2240_2257del COSV51767961

 

Supporting data and figures

Resources

Kit Handbooks (1)
Quick-Start Protocols (1)
Safety Data Sheets (1)