RNeasy 96 QIAcube HT Kit – Automated RNA Isolation

For automated high-throughput isolation of RNA from animal and human cells and tissue

S_3615_LS_Rneasy_s

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

RNeasy 96 QIAcube HT Kit (5)

Cat. No. / ID:   74171

For 480 preps: RNeasy 96 plates, RNase-free water, buffers
¥183,000
KitAccessories
RNeasy 96 QIAcube HT Kit
QIAcube HT Plasticware
The RNeasy 96 QIAcube HT Kit is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Simple and reliable automated processing for time and cost savings
  • Flexible procedures for isolating total RNA or total RNA, including miRNA
  • Protocols for various starting materials and desired size distribution
  • High-quality purified RNA ready for use in any downstream application
  • Consistent RNA yields from small amounts of starting material

Product Details


The RNeasy 96 QIAcube HT Kit enables simple, automated purification of total RNA or total RNA, including miRNA, from animal and human cells and tissue samples on the QIAcube HT system. Using proven RNeasy silica-membrane technology in a convenient 96-well format, contaminants and inhibitors are removed to yield high-quality RNA ready for downstream analysis.

Performance

Purification of RNA on QIAcube HT is simple and reliable with the RNeasy 96 QIAcube HT Kit and provides linear sample recovery with no significant well-to-well variation across a 96-well plate (see figure  Linear RNA recovery and  Reproducible 96-well RNA purification).
This economical, easy-to-use system provides the same results as other trusted QIAGEN purification technologies (see figure  Automated purification of RNA from tissues). Analysis of QIAcube HT purified samples shows high RNA Integrity Scores (RIS) when analyzed with the QIAxcel Advanced system, and performance similar to other automated QIAGEN purification solutions (see figure  High-quality RNA from tissues).
The RNeasy 96 QIAcube HT Kit provides consistent yields from small amounts of starting sample material (see table Typical total RNA yields from cells with the RNeasy 96 QIAcube HT Kit).
Typical total RNA yields from cells with the RNeasy 96 QIAcube HT Kit
Cell line Source RNA yield
(µg per 105 cells)*
HeLa Human cervical carcinoma 1.6
LMH Chicken hepatoma 1.3
COS-7 Monkey kidney, SV-40 transformed 3.1
Huh7 Human hepatoma 2.0
Jurkat Human T-cell leukemia 1.4
K-562 Human chronic myelogenous leukemia in blast crisis 1.9

See figures

Principle

The RNeasy 96 QIAcube HT Kit enables automated purification of total RNA or total RNA, including miRNA, from 5 x 105 animal or human cells or <40 mg tissue using the QIAcube HT instrument. Six instrument protocols are available, depending on the starting material and desired size distribution of purified RNA. Cell samples can be purified directly using the RNeasy 96 QIAcube HT Kit and the dedicated kit protocol. Tissue samples (<40 mg) and samples for purification of small RNA are processed following sample lysis in QIAzol Lysis Reagent. The procedures yield high-quality RNA that performs well in downstream applications.
The RNeasy 96 QIAcube HT Kit combines the selective binding properties of a silica-based membrane with a high-throughput 96-well format, and is designed for fully-automated, simultaneous processing of 24–96 samples on the QIAcube HT instrument.

Specifications for purification of total RNA from cells
Specification Description
Number of samples 24–96 samples (to be processed in increments of 8)
Sample input volume Up to 5 x 105 cells, homogenized in 140 μl Buffer RLT
Elution volume 110 μl
Duration 96 samples in approximately 93 or 114* minutes
24 samples in approximately 54 or 73* minutes

 

Specifications for purification of total RNA from tissues
Specification Description
Number of samples 24–96 samples (to be processed in increments of 8)
Sample input volume 350 μl aqueous phase from up to 40 mg frozen or 20 mg
stabilized tissue homogenized in 750 μl QIAzol Lysis Reagent
Elution volume 110 μl
Duration 96 samples in approximately 73 or 93* minutes
24 samples in approximately 34 or 54* minutes

 

Specifications for purification of total RNA, including miRNA, from cells or tissue
Specification Description
Number of samples 24–96 samples (to be processed in increments of 8)
Sample input volume 350 μl aqueous phase from up to 40 mg frozen or 20 mg
stabilized tissue homogenized in 750 μl QIAzol Lysis Reagent
Elution volume 110 μl
Duration 96 samples in approximately 78 minutes
24 samples in approximately 38 minutes

Procedure

Cell lysis is performed manually under highly denaturing conditions with guanidine thiocyanate to immediately inactivate RNases and ensure purification of intact RNA. After the run is started, ethanol is added to the lysate to provide appropriate binding conditions, and the samples are then applied to the wells of the RNeasy 96 plate. Total RNA binds and contaminants are efficiently washed away. High-quality RNA is then eluted in a small volume of RNase-free water, ready for use in any downstream application.
With the automated procedure for purification of total RNA from animal or human cells, all RNA molecules longer than 200 nucleotides are purified. This provides enrichment for mRNA, since most RNAs <200 nucleotides (such as 5.8S rRNA, 5S rRNA, and tRNA, which together comprise 15–20% of total RNA) are selectively excluded. The size distribution of the purified RNA is comparable to that obtained by centrifugation through a CsCl cushion, where small RNA does not sediment efficiently.
For purification of total RNA from tissue, or of total RNA including small RNA, from cells and tissues, we recommend first using QIAzol Lysis Reagent as the lysis buffer. Detailed procedures are provided in the kit handbook.

Applications

The RNeasy 96 QIAcube HT Kit provides efficient, high-throughput RNA sample preparation for research use in fields such as drug screening and basic research. The purified RNA is ready to use in any downstream application, including:

  • RT-PCR and qRT-PCR
  • Differential display
  • cDNA synthesis
  • Northern, dot, and slot blot analyses
  • Primer extension
  • Poly A+ RNA selection
  • RNase/S1 nuclease protection

Supporting data and figures

Resources

Protocol Files (12)
Installation file (.msi) for installing the Q Protocol run file (.qsp) in the QIAcube HT software. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Installation file (.msi) for installing the Q Protocol run file (.qsp) in the QIAcube HT software. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Q Protocol notes for purification of total RNA from animal or human cells, including DNase digestion, on the QIAcube HT using the RNeasy 96 QIAcube HT Kit; use with the RNeasy 96 QIAcube HT total RNA Cell with DNase V1.qsp run file. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Installation file (.msi) for installing the Q Protocol run file (.qsp) in the QIAcube HT software, For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Q Protocol notes for purification of total RNA from animal or human cells on the QIAcube HT using the RNeasy 96 QIAcube HT Kit; use with the RNeasy 96 QIAcube HT total RNA Cell V1.qsp run file. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Installation file (.msi) for installing the Q Protocol run file (.qsp) in the QIAcube HT software. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Q Protocol notes for automatic transfer of upper aqueous phase to an empty S-Block on the QIAcube HT using the RNeasy 96 QIAcube HT Kit; use with the RNeasy 96 QIAcube HT pre-treatment V1.qsp run file. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Q Protocol notes for purification of total RNA from tissue on the QIAcube HT using the RNeasy 96 QIAcube HT Kit; use with the RNeasy 96 QIAcube HT total RNA Tissue V1.qsp run file. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Installation file (.msi) for installing the Q Protocol run file (.qsp) in the QIAcube HT software. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Installation file (.msi) for installing the Q Protocol run file (.qsp) in the QIAcube HT software. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Q Protocol notes for purification of total RNA or total RNA, including miRNA, from animal tissue and cells on the QIAcube HT using the RNeasy 96 QIAcube HT Kit; use with the miRNeasy 96 QIAcube HT V1.qsp run file. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Q Protocol notes for purification of total RNA from tissue, including DNase digestion, on the QIAcube HT using the RNeasy 96 QIAcube HT Kit; use with the RNeasy 96 QIAcube HT total RNA Tissue with DNase V1.qsp run file. For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software.
Safety Data Sheets (1)
Quick-Start Protocols (4)
For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software
For use with QIAcube HT Prep Manager Software; not compatible with QIAcube HT Operating Software 4.17
For use with the RNeasy 96 QIAcube HT Kit and QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software
For use with QIAcube HT Operating Software 4.17; not for use with QIAcube HT Prep Manager Software
Kit Handbooks (2)
Handbook for purification of total RNA, or total RNA, including miRNA, from animal tissue and cells on the QIAcube HT using the RNeasy 96 QIAcube HT Kit. For use with QIAcube HT Operating Software 4.17; not compatible with QIAcube HT Prep Manager Software.
For use with QIAcube HT Prep Manager Software; not compatible with QIAcube HT Operating Software 4.17
Instrument User Manuals (1)
For use with the QIAcube HT Prep Manager Software
Certificates of Analysis (1)

FAQ

Can I run the QIAcube HT with the QIAxtractor software or vice versa?

No, the two software applications are not interchangeable.

 

Additionally, the QIAcube HT and QIAxtractor software cannot be installed on the same computer. The QIAcube HT software versions is v4.17 or higher, while the QIAxtractor software version is v4.16 or lower.

FAQ ID -9102
For what batch size is the QIAcube HT Plasticware designed?
The QIAcube HT Plasticware content is calculated for use with the extraction protocol working in batches of 96 samples. If running smaller batches and/ or the transfer protocol, additional consumables are required. 
FAQ ID - 4010
Can I upgrade a Corbett CAS-1820 to a QIAcube HT?

No, this upgrade is not possible.

FAQ ID -9104
What file is required for reporting a QIAcube HT or QIAxtractor issue?

The Support Packages are important when reporting an issue to QIAGEN Technical Services. Upon completion of each run, the software automatically saves a support package.

 

To retrieve a support package, click Help in the QIAcube HT or QIAxtractor software and select Choose support package. In the new windows, select the support package that corresponds to the issue and send it to QIAGEN Technical Services.

 

FAQ ID -9100
I am getting vacuum errors on my QIAcube HT. What should I do?

1. Check the vacuum tubing to make sure it is not pinched or obstructed in some way. Sometimes the tubing can become pinched against the bench top when the vacuum station is placed too far from the instrument.

Waste bottle tubing

2. Make sure that the channeling adapter is properly placed. Check if the carriage is moving the plate completely from the waste chamber position to the elution chamber position. If the calibration seems incorrect, the instrument may need to be re-taught at this position.

Adaptors

3. When using less than a full plate, make sure all the unused columns are covered with an adhesive seal.

Also, make sure each column of 8 samples is full. When processing a number of samples that results in < 8 samples per column, use water as a substitute in the empty positions until the column is filled. This ensures even vacuum across all unsealed well positions.

4. Make sure correct plates are used for the selected protocol.

5. When the vacuum is on, please listen for any hissing noise from the tubing that is coming down to the waste container. This could indicate leaks in the tubing.

If the issue persists, please contact QIAGEN Technical Service.



FAQ ID -9106
What do I do if the QIAcube HT or QIAxtractor software runs in virtual mode while the instrument is connected to the computer?

Make sure the QIAcube HT or QIAxtractor software uses the same COM port number as assigned to the QIAcube HT or QIAxtractor instrument on the computer. The COM port setting can be checked by clicking Options\Robot Setup\Select COM port in the QIAcube HT or QIAxtractor software.

 

Ensure that the cable between the instrument and the computer is securely inserted. Power on the instrument first, and then launch the QIAxtractor/QIAcube HT software. 

 

The instrument has both RS-232 (serial) and USB interfaces for computer connection. Try an RS-232 cable if the communication cannot be established between the instrument and computer with a USB cable.

 

If the issue persists, please contact QIAGEN Technical Services.

 

FAQ ID -9101