Rotor-Gene AssayManager

For routine testing with Rotor-Gene Q and QIAsymphony RGQ instruments

S_1084_5_GEN_V2

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Rotor-Gene AssayManager

Cat. No. / ID:   9022737

Software for routine testing in combination with the Rotor-Gene Q and QIAsymphony RGQ instruments; single license software for installation on one computer
Licences
1
10
For up-to-date licensing information or Rotor-Gene Q instrument specific disclaimers, refer to the corresponding Rotor-Gene Q instrument manual.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Standardized, fully automated real-time PCR analysis
  • Maximized process safety and ease of use
  • Unprecedented flexibility for all routine testing demands
  • Supports self-validated user-defined tests
  • Enhanced lab productivity with optimized workflows

Product Details

Rotor-Gene AssayManager software is used in combination with Rotor-Gene Q MDx and QIAsymphony RGQ instruments for routine testing. This intuitive software manages all tasks associated with running real-time PCR assays offering enhanced convenience, standardization, and flexibility. Fully automated analysis and interpretation of results minimizes human error, delivering results you can trust.

Principle

Rotor-Gene AssayManager is able to read in sample information, set up experiments, control up to 4 different Rotor-Gene Q cyclers, acquire data from these instruments, automatically analyze results, and create reports. All information on how to run, analyze, interpret, and report an assay is stored in the easy-access Rotor-Gene AssayManager database. Comprehensive user guidance and well-defined workflows facilitate increased standardization and laboratory productivity. In addition, Rotor-Gene AssayManager supports the latest quality and usability requirements for software, such as 21 CFR Part 11.
Rotor-Gene AssayManager enables:
  • Operation of up to 4 Rotor-Gene Q cyclers from one computer
  • Individual or network installation with remote access
  • Convenient and reliable data management
  • Secure user management
  • Data import/export from QIAsymphony instruments, LIMS, QIAGEN LIMS middleware
  • Fully automated analysis and interpretation of results
  • Use of an editor to set up user-validated workflows (User Defined Test mode)

Procedure

Comprehensive user guidance with flexible options
With standardized color schemes, easy-to-understand icons, and comprehensive help and warning messages the user is guided step-by-step through Rotor-Gene AssayManager software.The seamless connection of Rotor-Gene AssayManager to automated upstream sample processing and assay setup with QIAsymphony SP/AS instruments guarantees highest workflow convenience and process safety. In addition, manual up-front processing steps are supported by a special editor, step-by-step procedures, automatic barcode reading, and other features.
Control of up to 4 Rotor-Gene Q cyclers and remote access
Rotor-Gene AssayManager controls the Rotor-Gene Q cycler, i.e., the software will provide all functions to set up, start, and run real-time PCR experiments on up to 4 Rotor-Gene Q cyclers in parallel (see figure " Increased lab efficiency"). This saves laboratory space and increases lab efficiency.
Rotor-Gene AssayManager can also be used for experiment setup, result approval, or reporting on computers not connected to a Rotor-Gene Q cycler. In this case, the software can be installed on the user's office computer enabling convenient result review and approval. Alternatively, a computer in the assay setup room may be used for run setup. This networking capability together with secure database management simplifies a variety of everyday tasks.
Fully automated real-time PCR analysis
Automated real-time PCR analysis is the core function of Rotor-Gene AssayManager. Rotor-Gene AssayManager analyzes the real-time PCR raw data according to well-defined assay specific rules and generates result reports comprising information on the validity or invalidity of the assay and individual samples (see figure " Automated result reporting"). The software provides a special editor to set up all rules and other characteristics for your user defined test.Reliable data management
Rotor-Gene AssayManager imports sample-specific information from QIAsymphony instruments, from a LIMS, from a dedicated QIAGEN LIMS middleware solution (in preparation), or from separate Rotor-Gene AssayManager installations. All data from all installations and from all Rotor-Gene Q cyclers in your lab can be stored in a central database. After analysis, approval, and reporting (e.g., as a printout, PDF, or LIMS export), the data are moved to a common electronic archive. For fast and easy data access of all data at each time point, the database is searchable by using various filter functions.
Secure user management
Different user profiles are available and are password protected (user login is required) for increased security. Operators set up and start a run, while administrators are responsible for managing all assets (e.g., cyclers, assay profiles, users) necessary for working with Rotor-Gene AssayManager. Approvers accept or reject the results of a run and release the data of an experiment. Assignment of these dedicated user roles enables optimal use of resources for your laboratory tasks.
Support of 21 CFR Part 11 compliance
Rotor-Gene AssayManager includes specific features that support the technical requirements of 21 CFR Part 11 regulations, enabling use of an electronic records system. User accounts are password-protected according to CLIA requirements and all user actions are documented in an audit trail that can be filtered and printed out. The Rotor-Gene AssayManager audit trail is designed based on guidelines in FDA CFR Title 21, Part 11 Electronic Records, Electronic Signatures.
Software that meets the demands of routine testing applications — today and tomorrow
Rotor-Gene AssayManager standardizes procedures such as cycler control and data storage, helping to reduce the burden of multiple standard operating procedures and simplifying laboratory documentation (see figure " Standardized workflow"). Full flexibility is retained through the use of modular plug-ins that ensure future assays and different assay designs can be run with the workflow already established in your laboratory.
See figures

Applications

Rotor-Gene AssayManager enables user defined tests using Rotor-Gene Q and QIAsymphony RGQ instruments in routine testing laboratories.

Supporting data and figures

Resources

Instrument User Manuals (7)
For creation of Rotor-Gene AssayManager assay profiles (only available for the User Defined Test [UDT] mode)
For general use of Rotor-Gene AssayManager
For installation and setup of Rotor-Gene AssayManager
For installation and setup of Rotor-Gene AssayManager
For use of Rotor-Gene AssayManager in User Defined Test (UDT) mode in combination with the UDT Basic Plug-in
For use of Rotor-Gene AssayManager with assays requiring the Epsilon Plug-in
Safety Data Sheets (1)
Protocol Files (7)
To run and analyze QIAGEN artus PCR kits with the Rotor-Gene AssayManager additionally specific assay profiles need to be imported into the database.
The information about which assay profile is needed for which application is provided in the application sheets on the corresponding artus kit web catalog pages.
artus basic plug-in V1.0.4
SOFTWARE (13MB)
To run and analyze QIAGEN artus PCR Kits with Rotor-Gene AssayManager, specific assay profiles need to be imported into the database.
The information about which assay profile is needed for which application is provided in the application sheets or handbook on the corresponding artus Kit web catalog pages.
Report profile for use with the artus basic plug-in V1.0.3 in combination with Rotor-Gene AssayManager
To run and analyze assays with Rotor-Gene AssayManager version 1.0
To run and analyze assays with Rotor-Gene AssayManager version 1.0
Software Release Notes (1)
Certificates of Analysis (1)