RT2 SYBR® Green FAST Mastermixes

For use with 100-ring disc format RT2 Profiler and RT2 lncRNA PCR Arrays on the Rotor-Gene Q

Products

RT2 SYBR® Green FAST Mastermixes are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.
Image

RT² SYBR Green ROX FAST Mastermix (2)

Cat. No. / ID:   330620

Contains 2 x 1.35 ml tubes: for 12 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 250 x 20 µl reactions
349,00 €
Image

RT² SYBR Green FAST Mastermix (8)

Cat. No. / ID:   330601

Contains 8 x 1.35 ml tubes: for 8 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 1000 x 20 µl reactions
1 293,00 €
Image

RT² SYBR Green ROX FAST Mastermix (24)

Cat. No. / ID:   330623

Contains 24 x 1.35 ml tubes: for 24 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 3000 x 20 µl reactions
2 940,00 €
Image

RT² SYBR Green ROX FAST Mastermix (25 ml)

Cat. No. / ID:   330629

Contains 1 bottle of 25 ml mastermix: for 24 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 2500 x 20 µl reactions
2 582,00 €
Image

RT² SYBR Green FAST Mastermix (12)

Cat. No. / ID:   330602

Contains 12 x 1.35 ml tubes: for 12 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 1500 x 20 µl reactions
1 840,00 €
Image

RT² SYBR Green ROX FAST Mastermix (8)

Cat. No. / ID:   330621

Contains 8 x 1.35 ml tubes: for 8 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 1000 x 20 µl reactions
1 293,00 €
Image

RT² SYBR Green FAST Mastermix (2)

Cat. No. / ID:   330600

Contains 2 x 1.35 ml tubes: for 2 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 250 x 20 µl reactions
349,00 €
Image

RT² SYBR Green ROX FAST Mastermix (12)

Cat. No. / ID:   330622

Contains 12 x 1.35 ml tubes: for 12 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 1500 x 20 µl reactions
1 869,00 €
Image

RT² SYBR Green FAST Mastermix (24)

Cat. No. / ID:   330603

Contains 24 x 1.35 ml tubes: for 24 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 3000 x 20 µl reactions
2 940,00 €

Features

  • Designed for 100-ring disc RT2 Profiler / RT2 lncRNA PCR Arrays
  • Available with ROX, fluorescein, or without dye
  • Well-suited for use with self-designed PCR assays
  • Exceptional qPCR performance in instruments with fast cycling conditions

Product Details

RT2 SYBR Green FAST Mastermixes are specially formulated for use with the 100-ring disc format of the RT2 Profiler and RT2 lncRNA PCR arrays on the Rotor-Gene Q. This mastermix is suited for use with self-designed qPCR assays on other types of real-time PCR instruments with fast cycling conditions. RT2 SYBR Green FAST Mastermixes are available with ROX, fluorescein, or without reference dyes.

Performance

RT² SYBR Green FAST Mastermixes contain all of the optimized reagents and buffers needed for SYBR Green based real-time PCR with RT2 qPCR Primer Assays and RT2 Profiler PCR Arrays on all real-time PCR instruments.

The high-performance real-time PCR enabled by RT² SYBR Green FAST Mastermixes demonstrates high amplification efficiencies (see figure " High amplification efficiency over a wide dynamic range") and high levels of sensitivity and specificity (see figure " Tighter control of polymerase activity yields greater specificity").

In addition, dissociation curves obtained using RT2 SYBR Green FAST Mastermixes have lower background and a sharper shape compared with dissociation curves generated by regular cycling conditions (see figure " Sharper dissociation curves with RT2 SYBR Green Fast Mastermix").

See figures

Principle

RT2 SYBR Green FAST Mastermixes contain real-time PCR buffer, a high-performance, HotStart DNA Taq polymerase, nucleotides, and SYBR Green dye. Some mastermixes contain either fluorescein or ROX dye for optimization of the instrument optics. The chemically-modified and tightly controlled HotStart enzyme uniquely provides accurate SYBR Green results by preventing the amplification of primer–dimers and other nonspecific products. RT2 SYBR Green FAST Mastermixes are optimized to use a 10-second denaturation step and 30-second annealing/extension step PCR protocol, without compromising specificity or sensitivity.

Mastermixes without ROX or fluorescein

RT2 SYBR Green FAST Mastermix is highly suited for real-time PCR applications using SYBR Green-based detection on instrumentation not requiring a reference dye, including Bio-Rad models CFX96, CFX384; Bio-Rad/MJ Research Chromo4, DNA Engine Opticon, DNA Engine Opticon 2; Roche LightCycler 480 (96-well and 384-well); Eppendorf  Mastercycler  ep realplex without ROX filter set; and Cepheid SmartCycler.

Mastermixes with fluorescein

RT2 SYBR Green Fluor FAST Mastermix is highly suited for real-time PCR applications using SYBR Green-based detection on instrumentation that uses fluorescein as a reference dye, including the Bio-Rad models iCycler, iQ5, MyiQ, and MyiQ2.

Mastermixes with ROX

RT2 SYBR Green ROX FAST Mastermix is highly suited for real-time PCR applications using SYBR Green-based detection on instrumentation that uses ROX as a reference dye, including QIAGEN’s Rotor-Gene Q; Applied Biosystems models 5700, 7000, 7300, 7500 (Standard and Fast), 7700, 7900HT  (Standard and Fast 96-well block, 384-well block), StepOnePlus, ViiA 7 (Standard and Fast 96-well block, 384-well block); Eppendorf Mastercycler ep realplex with or without ROX filter set; Stratagene models Mx3000P, Mx3005P, Mx4000; and Takara TP-800.

Applications

RT2 SYBR Green FAST Mastermixes are suitable for use in real-time PCR applications.

Supporting data and figures

Resources

Safety Data Sheets (1)
Kit Handbooks (1)
For pathway-focused gene expression profiling using real-time RT-PCR
Certificates of Analysis (1)

FAQ

Are primers available that only detect mitochondrial DNA encoded genes and not nuclear genomic DNA encoded genes?
There are less than a dozen genes encoded by the mitochondrial genome (all other mitochondrial proteins are encoded by nuclear genes), and they are all transcribed as one transcript (just like any prokaryote), so distinguishing the expression of individual genes by real-time RT-PCR is not possible.
FAQ ID -2680
How can I ensure that reaction volume is not lost due to evaporation during thermal cycling?
Be sure to carefully and completely seal the qPCR assay plate with fresh, optical, thin-wall, 8-cap strips or adhesive optical film before the plate is placed into the real-time cycler. In addition, refer to your instrument's user's manual to determine whether the real-time cycler manufacturer recommends use of a plate compression pad during the run.
FAQ ID -2679
How do I create a workspace that is free of DNA contamination, prior to carrying out a qPCR experiment?

Any DNA contamination will artificially inflate the SYBR Green signal, yielding skewed gene expression profiles and false-positive signals. The most common source of DNA contamination is from PCR products generated during previous experiments. Such contamination is most often due to the improper disposal of tubes, tips, and gels that previously came into contact with PCR products. Additionally, PCR products may also contaminate pipettors, racks, work pads, and commonly used reagents such as water and buffers. To minimize the risk of contaminating your experiment with extraneous DNA, the following steps should be taken:

 

  • Remove a single aliquot of water from your PCR-grade stock, sufficient to complete the experiment. This minimizes the number of times that the stock container is opened, thereby minimizing contamination risks.
  • Use only fresh PCR-grade reagents and disposable labware.
  • Treat any labware (tubes, tips, and tip boxes) used in PCR with 10% bleach, before discarding.
  • Maintain a dedicated workspace for PCR setup (perhaps a PCR-only hood), away from areas of the lab where post-PCR work is done, such as running gels, enzyme digestions, and cloning.
  • Change the lab bench pads/papers often and decontaminate lab benches and labware (racks, pipettors, etc.) before each use by washing with 10% bleach, and/or exposing to UV light for at least 10 minutes. This serves to degrade and/or inactivate contaminating DNA.
  • Before, during, and after the experiment, minimize the opening and closing of any tubes or plates used during the experiment.  
FAQ ID -2654
What is a dissociation curve, and why is it important to run a dissociation curve, following qPCR using SYBR Green chemistry?

Dissociation curves are carried out at the end of a PCR experiment by following a 3-step procedure.

First, all the components are denatured at 95°C, followed by complete annealing at a set temperature (based on the primer Tm values), followed by a gradual increase in temperature up to 95°C. Fluorescence intensity is monitored during this final temperature increase, resulting in the generation of a melting curve or dissociation curve.

By analyzing the first derivative of such a curve, you can readily assess the homogeneity of the PCR products, including the presence of primer–dimers, thereby determining the specificity of the PCR reaction. It is important to carry out such post-PCR analyses when using SYBR Green probe chemistry due to this reagent's lack of sequence specificity.

FAQ ID -2678