QIAquick PCR Purification Kit for PCR Cleanup

Para la purificación de hasta 10 µg de productos de PCR, entre 100 bp y 10 kb

✓ Procesamiento automático sin interrupción de pedidos en línea

✓ Servicio técnico y para productos experto y profesional

✓ Realización y repetición de pedidos rápidas y fiables

QIAquick PCR Purification Kit (50)

Cat. No. / ID:   28104

Para la purificación de 50 reacciones de PCR: 50 QIAquick Spin Columns, tampones, Collection Tubes (2 ml)
KitColumna
QIAquick PCR Purification Kit
QIAquick PCR & Gel Cleanup Kit
QIAquick Spin Columns
Preparaciones
50
250
1000
El QIAquick PCR Purification Kit está concebido para su uso en aplicaciones de biología molecular. Este producto no está concebido para el diagnóstico, la prevención ni el tratamiento de enfermedades.

✓ Procesamiento automático sin interrupción de pedidos en línea

✓ Servicio técnico y para productos experto y profesional

✓ Realización y repetición de pedidos rápidas y fiables

Características

  • Hasta 95 % de recuperación de ADN listo para usarse
  • Limpieza de ADN de hasta 10 kb en tres sencillos pasos
  • Colorante de carga de gel para el análisis práctico de muestras
  • Kit combinado para la extracción en gel y la limpieza de PCR
  • Las columnas de centrifugación están disponibles por separado 

Detalles del producto

El QIAquick PCR Purification Kit incluye columnas de centrifugación, tampones y tubos de recogida para la purificación basada en membrana de gel de sílice de productos de PCR >100 bp. Se purifica el ADN de hasta 10 kb mediante un procedimiento sencillo y rápido de unión, lavado y elución y un volumen de elución de 30–50 μl. Un indicador de pH opcional permite determinar con facilidad el pH óptimo para la unión de ADN a la columna de centrifugación. El procedimiento se puede automatizar por completo en el instrumento QIAcube Connect.

Para obtener resultados óptimos, se recomienda utilizar este producto junto con QIAvac 24 Plus.

Los protocolos estándar de QIAquick PCR Purification también pueden llevarse a cabo mediante el uso del sistema TRACKMAN Connected, combinado con las pipetas PIPETMAN M Connected, ambos de Gilson. El sistema TRACKMAN Connected orienta a los investigadores a lo largo de los protocolos de QIAquick PCR Purification al tiempo que se ajustan automáticamente los parámetros de la pipeta PIPETMAN M Connected con Bluetooth. Cada paso de la ejecución del protocolo se registra para acelerar la elaboración de informes mediante la generación de un informe completo de la serie. Descargar más información.

Rendimiento

El procedimiento de QIAquick PCR Purification elimina cebadores, nucleótidos, enzimas, aceites minerales, sales y otras impurezas de las muestras de ADN (consulte la figura « Eliminación completa de cebadores tras la PCR»). Con el uso de una microcentrifugadora o un colector de vacío, se purifica el ADN que oscila entre 100 bp y 10 kb.
Ver figuras

Principio

Los kits QIAquick contienen un ensamblaje de membrana de sílice para la unión del ADN en tampón de alta salinidad y elución con tampón de baja salinidad o agua. El procedimiento de purificación elimina cebadores, nucleótidos, enzimas, aceites minerales, sales, agarosa, bromuro de etidio y otras impurezas de las muestras de ADN (consulte la figura « Eliminación completa de cebadores tras la PCR»). La tecnología de membrana de sílice elimina los problemas e inconvenientes relacionados con las resinas sueltas y los residuos pastosos. Los tampones de unión especializados están optimizados para aplicaciones específicas y promover la adsorción selectiva de moléculas de ADN dentro de rangos de tamaño específicos.

Colorante de carga de gel

Para que el procesamiento y el análisis de las muestras sean más rápidos y prácticos, se proporciona el colorante de carga de gel. El GelPilot Loading Dye contiene tres colorantes de seguimiento (xileno cianol, azul de bromofenol y naranja G) para facilitar la optimización del tiempo de la serie del gel de agarosa y evitar que los fragmentos más pequeños de ADN migren demasiado lejos (consulte la figura « GelPilot Loading Dye »).

Ver figuras

Procedimiento

El sistema QIAquick emplea un procedimiento sencillo de unión, lavado y elución (consulte el diagrama de flujo « Procedimiento de QIAquick y MinElute»). El tampón de unión se añade directamente a la muestra de PCR u otras reacciones enzimáticas y la mezcla se aplica a la QIAquick Spin Column. El tampón de unión contiene un indicador de pH, lo que permite determinar con facilidad el pH óptimo para la unión del ADN (consulte la figura  «Colorante indicador de pH»). Los ácidos nucleicos se adsorben a la membrana de sílice en las condiciones de alta salinidad generadas por el tampón. Se lavan las impurezas y el ADN puro se eluye con un volumen bajo del tampón de baja salinidad suministrado o de agua, listo para usarse en todas las aplicaciones posteriores.

Manejo

Las QIAquick Spin Columns se han diseñado con dos prácticas opciones de manejo. Las columnas de centrifugación se adaptan a una microcentrifugadora de mesa convencional o a cualquier colector de vacío con conectores Luer, como QIAvac 24 Plus con QIAvac Luer Adapters. El QIAquick PCR Purification Kit, junto con otros kits basados en columnas de centrifugación de QIAGEN, se puede automatizar por completo en el instrumento QIAcube, lo que permite incrementar la productividad y la normalización de los resultados (consulte las figuras «Opciones de manejo de la columna de centrifugación  A,  B,  C y  D» y « QIAcube Connect»).

Ver figuras

Aplicaciones

Los fragmentos de ADN purificados con el sistema QIAquick están listos para su uso directo en diversas aplicaciones, incluyendo la secuenciación, el análisis de micromatrices, la ligación y transformación, la digestión de restricción, el marcado, la microinyección, la PCR y la transcripción in vitro.

Datos y cifras de respaldo

Specifications

FeaturesSpecifications
Binding capacity10 µg
TechnologyTecnología de sílice
Sample type: applicationsADNmc o ADNbc a partir de la PCR y otras reacciones enzimáticas
Fragments removed<40 mers
Elution volume>30 µl
Fragment size100 bp–10 kb
ProcessingManual
FormatTubo
Type(s) of DNA recoveredADNmc y ADNbc

FAQ

I bound an 11 kb DNA fragment to a QIAquick column; is it completely lost?

Larger DNA fragments bind more tightly to the QIAquick columns. It is difficult to predict whether a DNA fragment larger than 10 kb can be efficiently recovered, because this depends on base composition as well as fragment size. If the fragment is only a few kb larger than the 10 kb limit, it can be helpful to heat the elution buffer EB to 60°C and let it incubate on the column for a few minutes before centrifuging. However, please note that it will become less likely to recover your sample the larger the fragment size is. As we cannot guarantee recovery of fragments larger than the maximum cutoff size, we do not recommend to purify such fragments using QIAquick Kits.

The QIAEX II Kit can be used to extract DNA fragments up to 50 kb from agarose or polyacrylamide gels.

 

FAQ ID -756
Are Buffer PB of the QIAquick PCR Purification Kit and Buffer QG of the QIAquick Gel Extraction Kit interchangeable?

Buffer PB of the QIAquick PCR Purification Kit cannot be used to extract DNA from agarose gels. However, Buffer QG of the QIAquick Gel Extraction Kit can be used to remove salt and proteins from enzymatic reactions by adding 3 volumes of Buffer QG and 1 volume of isopropanol to the reaction and proceeding with step 6 of the Gel Extraction Spin Protocol in the QIAquick Spin Handbook. See the QIAquick Spin Handbook for a list of reactions which can be cleaned up with the various QIAquick kits.

FAQ ID -786
Are QIAprep and QIAquick Spin columns interchangeable?
No. While columns from the QIAprep Spin Miniprep Kit and the QIAquick PCR Purification- and Gel Extraction Kits are based on silica-gel-membrane technology, each is designed to work optimally within its own kit format. In addition, the binding capacity and DNA recovery size cut-offs of the QIAprep and QIAquick Spin columns are different. QIAprep Spin columns bind up to 20 ug of plasmid DNA up to 50 kb in length, while the QIAquick Spin columns bind up to 10 ug of DNA with a maximum fragment size of 10 kb.
FAQ ID -311
Are the columns of the QIAquick PCR Purification-, Gel Extraction-, and Nucleotide Removal Kit interchangeable?
Yes - all QIAquick Spin Kits contain identical columns, but different binding buffers optimized for each specific application.
FAQ ID -577
How can I improve recoveries when using the QIAquick Kits?

Buffer PE did not contain ethanol

Ethanol must be added to Buffer PE (concentrate) before use. Repeat procedure with correctly prepared Buffer PE.

Inappropriate elution buffer

DNA will only be eluted efficiently in the presence of low-salt buffer (e.g., Buffer EB: 10 mM Tris·Cl, pH 8.5) or water. Elution efficiency is strongly dependent on the salt concentration and pH of the elution buffer. Contrary to adsorption, elution is most efficient under basic conditions and low salt concentrations. DNA is eluted with 50 or 30 µl of the provided Buffer EB (10 mM Tris·Cl, pH 8.5), or water. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water to elute, make sure that the pH is within this range. In addition, DNA must be stored at –20°C when eluted with water since DNA may degrade in the absence of a buffering agent. Elution with TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0) is possible, but not recommended because EDTA may inhibit subsequent enzymatic reactions.

Elution buffer incorrectly dispensed

Add elution buffer to the center of the QIAquick membrane to ensure that the buffer completely covers the membrane. This is particularly important when using small elution volumes (30 µl).

FAQ ID -180
Can QIAquick Kits be used to clean up RNA samples?
Although it is possible to use the QIAquick Nucleotide Removal Kit and QIAquick PCR Purification Kit for RNA purification, the conditions are not optimized for RNA, nor are RNase-free conditions guaranteed. The RNeasy MinElute Cleanup Kit is recommended for clean-up, concentration and desalting of RNAs above 200 bases in length.
FAQ ID -490
Do CoralLoad dyes supplied in various QIAGEN PCR Kits interfere with downstream applications?

CoralLoad dyes supplied in PCR Kits such as, e.g., Taq, HotStarTaq, and TopTaq DNA Polymerase and TopTaq Master Mix do not interfere with most downstream enzymatic applications.

However, for reproducible results, purification of PCR products using the QIAquick or MinElute PCR Purification Kits prior to enzymatic manipulation is recommended.

 

 

FAQ ID -1745
How do I perform a DNA precipitation to concentrate my sample?
  • Add 1/10 volume of 3 M Na-Acetate pH 5.2, and 2 to 2.5 volumes of ice-cold 100% ethanol to the DNA sample
  • Mix, and store at –20°C for at least 1 h to precipitate the DNA
  • Recover the precipitated DNA by centrifugation at full speed in a microcentrifuge for 15–20 min
  • Pour off the ethanol and wash the pellet twice with room-temperature 70% ethanol
  • Allow the DNA pellet to air-dry
  • resuspend the DNA in a suitable volume of sterile TE buffer or distilled water
FAQ ID -305
Do you have a protocol for purification of DNA fragments from Cy3/Cy5 dye-label reactions?
Yes, please follow the Supplementary Protocol 'Purification of DNA fragments from dye-labeled reactions using the QIAquick PCR Purification Kit' (QQ06). 
FAQ ID -947
What is the composition of Buffer PB?
Buffer PB contains a high concentration of guanidine hydrochloride and isopropanol. The exact composition of Buffer PB is confidential. However, this buffer can be purchased separately: Buffer PB.
FAQ ID -2791
Will the QIAquick PCR Purification Kit remove sufficient SYBR Green from real-time PCR reactions to allow sequencing?

Based on our experience, the QIAquick PCR Purification Kit removes SYBR Green dye efficiently from PCR reactions.

We strongly assume that the QIAquick Gel Extraction Kit will be equally efficient in removing this dye, however, we recommend a 5 min incubation with wash Buffer PE on the QIAquick spin column at step 10 of the QIAquick Gel Extraction Kit Protocol. Efficiency of SYBR Green dye removal has to be validated by the enduser.

 

FAQ ID -637
Do I have to remove the oil from my PCR reaction before using the QIAquick or MinElute PCR Purification Kit?
No - mineral oil will not affect the clean-up procedure with the QIAquick or MinElute PCR Purification Kit.
FAQ ID -575
Can I use the QIAquick PCR Purification Kit for restriction enzyme cleanup?

Yes. The QIAquick PCR Purification Kit has been used to clean up fragments between 100 bp and 10 kb from a wide range of enzymatic reactions, removing salts, buffers, enzymes, nucleotides, and primers smaller than 40 nucleotides. Reactions that can be cleaned up with the QIAquick PCR Purification Kit include restriction digests, random priming, ligase, kinase, phosphatase, nuclease, nick translation, and cDNA synthesis reactions.
For data and additional information, please see QIAGEN News article Issue No. 5, 1998 "Fast and efficient enzyme removal with QIAquick Spin kits."

FAQ ID -130
Why does my DNA sample float out of the slot when loading it onto an agarose gel?

DNA fragments purified with the QIAGEN DNA Cleanup Systems, i.e., the QIAquick PCR Purification Kit, the MinElute Reaction Cleanup Kit, the QIAEX II Gel Extraction Kit etc. may float out of the loading wells of agarose gels due to residual ethanol carried over from the wash step with Buffer PE (despite the addtition of glycerol-containing loading buffer).

Use either of the following options to remove residual ethanol from the eluate:

  • re-purify the sample using a QIAquick-, or MinElute column, or QIAEX II resin
  • incubate the eluate at 56°C for 10 min to evaporate the ethanol
  • dry down the sample in a vacuum centrifuge, and resuspend the pellet in a small volume of sterile water
FAQ ID -205
Is it possible to clean up a methylation reaction containing bisulfite with QIAquick Cleanup Kits?
Yes, bisulfite containing methylation reactions can be cleaned up with our silica-based cleanup products, such as QIAquick and QIAEX II. Please see Goyon et al. (1994),  'Perpetuation of cytosine methylation in Ascobolus immersus implies a novel type of maintenance methylase', published in J Mol Biol. 1994 Jul 1;240(1):42-51, for a reference.
FAQ ID -519
Do you have information about the cleanup of single-stranded DNA (ssDNA) with QIAquick columns?

As a rule of thumb, single-stranded DNA binds to silica with approximately half the affinity of a double-stranded DNA fragment of the same length under the buffer conditions used in the QIAquick and MinElute Kits. Even though no systematic experimental data exists, we expect that recovery of ssDNA fragments of approximately 200 nucleotides and below will not be very efficient after cleanup using the QIAquick PCR Purification Kit or MinElute PCR Purification Kit. By comparison, it should be possible to purify fragments longer than 140 nucleotides using the QIAquick Gel Extraction Kit.

Note that recovery of single strand DNA is influenced to some degree also by factors such as base composition and secondary structure. It has to be determined empirically by the researcher if cleanup of single-stranded DNA with QIAquick columns yields satisfactory results.

FAQ ID -759
What is the composition of Buffer EB?

The composition of Buffer EB is:

  • 10 mM Tris-Cl, pH 8.5

Buffer EB is the elution buffer used in the QIAquick PCR, Gel Extraction, Nucleotide Removal Kits, and MinElute Kits for DNA cleanup, and the QIAprep Miniprep Kits for small-scale plasmid purification. The purified DNA can also be eluted in TE (10 mM Tris-Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.

FAQ ID -199
What is the small band below my fragment of interest on an agarose gel after DNA cleanup using QIAquick?

Occasionally, DNA fragments eluted from the silica matrix of QIAquick, MinElute or QIAEX II Kits will contain denatured single-stranded DNA (ssDNA), appearing as a smaller band on an analytical gel. Under certain conditions, chaotropic agents (present in all silica-based DNA purification methods) can denature DNA fragments. This is a rare event that may be influenced by sequence characteristics such as the presence of inverted repeats or A–T-rich stretches.

Because salt and buffering agents promote renaturation of DNA strands, the following tips are recommended:

  • use the eluted DNA to prepare your downstream enzymatic reaction, but omit the enzyme. Incubate the reaction mix at 95°C for 2 minutes to reanneal the ssDNA, and allow the tube to cool slowly to room temperature before adding the enzyme and proceeding
  • alternatively, the DNA can be eluted from the silica-gel membrane or resin in 10 mM Tris buffer containing 10 mM NaCl. However, the salt concentration of the eluate must then be taken into consideration in downstream applications.
FAQ ID -148
Can I buy QIAquick and MinElute columns separately?

The QIAquick Spin Columns (100) (cat. no. 28115) in the QIAquick PCR Purification, Gel Extraction, Nucleotide Removal and PCR & Gel Cleanup kits are also sold separately from the kits.

The MinElute columns in the MinElute PCR Purification, Gel Extraction and Reaction Cleanup kits are not sold separately.

We always provide extra buffers in our kits so you can scale up reactions, add extra washes or allow for spillage.

FAQ ID -2460