✓ 24/7 automatic processing of online orders
✓ Knowledgeable and professional Product & Technical Support
✓ Fast and reliable (re)-ordering
Cat. No. / ID: 59124
✓ 24/7 automatic processing of online orders
✓ Knowledgeable and professional Product & Technical Support
✓ Fast and reliable (re)-ordering
Key features of the EpiTect Plus Bisulfite Kits include:
Effective conversion of DNA by treatment with sodium bisulfite must accomplish complete conversion of all unmethylated cytosines in the sample DNA while minimizing DNA degradation due to the harsh temperature and chemical conditions of the bisulfite conversion reaction. The protection of the treated DNA is a critical factor in the recovery rate of converted DNA and in the sensitivity of downstream applications. EpiTect Plus Bisulfite Kits facilitate effective bisulfite conversion of DNA while minimizing DNA degradation, with the added advantage of not requiring DNA isolation prior to the conversion reaction. This streamlines the workflow from sample lysis to final elution of converted DNA, providing rapid results and high-quality DNA ready to use in a variety of downstream applications.
The 3 EpiTect Plus Bisulfite Kits are interconnected, functioning as an integrated system of solutions for direct bisulfite conversion of DNA from a broad range of starting materials (see figure "Interconnected protocols"). However, each kit has unique features, addresses a specific sample type, and includes all buffers and reagents necessary to function independently. The components in each kit combine to deliver effective lysis of samples, minimal loss of DNA during lysis, complete bisulfite conversion, robust protection during conversion, and thorough cleanup of DNA.
The EpiTect Plus Bisulfite Kits do not replace the EpiTect Bisulfite Kits, but rather expand the types of samples that can be prepared for downstream applications requiring bisulfite converted DNA, and integrate the DNA preparation procedure. Both sets of kits include DNA Protect Technology and accomplish high conversion rates. EpiTect Bisulfite Kits offer a convenient 96-well format for high sample throughput. See table "QIAGEN solutions for DNA bisulfite conversion" for an overview of all 5 bisulfite conversion solutions in QIAGEN's Epigenetics portfolio to easily select the best kit for your application.
DNA Protect Buffer is uniquely formulated to prevent the fragmentation usually associated with bisulfite treatment of DNA at high temperatures and low pH values. It also provides effective DNA denaturation, resulting in the single-stranded DNA necessary for complete cytosine conversion. DNA Protect Buffer contains a pH indicator dye as a mixing control that allows confirmation of the correct pH for cytosine conversion (see figure " DNA Protect Buffer").
To extract DNA from FFPE samples, deparaffinization needs to be carried out. This is a process whereby paraffin is first dissolved and then removed, exposing samples for subsequent treatment with lysis buffer and proteinase K. Deparaffinization Solution is an innovative chemistry that facilitates deparaffinization with minimal handling. A great advantage of using Deparaffinization Solution is that it contributes to high DNA recovery rates. After addition to an FFPE sample, the solution remains on the sample while proteinase K digestion is carried out. There is no need to pellet the FFPE sample thereafter, or to remove paraffin-containing supernatant. Thus, the risk of sample loss during deparaffinization is avoided.
Feature | EpiTect Bisulfite Kit | EpiTect 96 Bisulfite Kit | EpiTect Plus DNA Bisulfite Kit | EpiTect Plus LyseAll Bisulfite Kit | EpiTect Plus FFPE Bisulfite Kit |
---|---|---|---|---|---|
Format | EpiTect spin column | 96-well plate | MinElute DNA spin column | MinElute DNA spin column | MinElute DNA spin column |
Starting material | gDNA | gDNA | gDNA | Whole blood, cells, tissues | FFPE tissue slices |
Input amount | 1 ng – 2 µg gDNA | 1 ng – 2 µg gDNA | 1 ng – 2 µg gDNA | 10–100,000 cells, 0.5–20 µl whole blood | 1 FFPE tissue slice (10 µm) |
Sample lysis step included? | No | No | No | Yes. Lysis Buffer FTB for cells, blood, and tissues is included | Yes. Deparaffinization Solution and Lysis Buffer FTB are included |
Elution volume | 20–40 µl | 40–50 µl | ≥10 µl | ≥10 µl | ≥10 µl |
Conversion efficiency | >99% | >99% | >99% | >99% | >99% |
Automation | QIAcube | No | QIAcube | QIAcube | QIAcube |
Centrifugation/vacuum protocol | Centrifugation | Centrifugation/vacuum | Centrifugation | Centrifugation | Centrifugation |
Kit composition | EpiTect Bisulfite Kit | EpiTect 96 Bisulfite Kit | EpiTect Plus DNA Bisulfite Kit | EpiTect Plus LyseAll Lysis Kit and EpiTect Plus DNA Bisulfite Kit | EpiTect Plus FFPE Lysis Kit and EpiTect Plus DNA Bisulfite Kit |
The EpiTect Plus DNA Bisulfite Kit includes carefully formulated buffers and reagents to provide streamlined and effective bisulfite conversion of genomic DNA and subsequent cleanup of the converted DNA (see figure " EpiTect Plus DNA flowchart"). With unique DNA Protect Technology and QIAGEN spin columns, this kit generates fully converted DNA with minimal degradation that can be eluted in as little as 10 µl of buffer for downstream applications requiring high DNA concentrations. This kit can be used for conversion of 1 ng – 2 µg DNA in a volume of 20 µl or 1–500 ng DNA in a volume of 40 µl.
The EpiTect Plus FFPE Bisulfite Kit consists of the EpiTect Plus FFPE Lysis Kit for the deparaffinization and lysis of FFPE tissue slices, and the EpiTect Plus DNA Bisulfite Kit for the effective bisulfite conversion of the DNA released from the samples (see figure " EpiTect Plus FFPE flowchart". The deparaffinization, lysis, and decrosslinking of FFPE slices is optimized with innovative Deparaffinization Solution and Lysis Buffer FTB, and a carefully designed reaction temperature protocol. The DNA released during lysis and decrosslinking is used directly for bisulfite conversion with the included EpiTect Plus DNA Bisulfite Kit. Input amount for this kit is single FFPE tissue slices of 10 µm in thickness.
The EpiTect Plus LyseAll Bisulfite Kit consists of the EpiTect Plus LyseAll Lysis Kit for lysis of whole blood cells, cells from culture, and fresh tissues, and the EpiTect Plus DNA Bisulftie Kit for the effective bisulfite conversion of the DNA released from these samples (see figure " EpiTect Plus LyseAll flowchart". Uniquely formulated lysis buffers streamline the release of DNA from samples, which can be used directly for bisulfite conversion without the need for prior isolation. This kit can be used with 0.5–20 µl blood or 10–105 cells (as little as 60 pg of DNA).
DNA converted and purified using EpiTect Plus Bisulfite Kits is suitable for use in a range of downstream applications including:
Depending on sample type, the bisulfite conversion of DNA calls for the use of a specific kit and protocol. Kits contain buffers optimized for DNA extraction and all reagents for the DNA bisulfite conversion.