EZ2 Connect MDx

For fast automated nucleic acid extraction in IVD workflows

S_1208_7_MDx_ST_EZConnect_0758

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

EZ2 Connect MDx

Cat. No. / ID:   9003230

Compact benchtop instrument for automated isolation of nucleic acids from up to 24 samples in parallel, using sealed prefilled cartridges; includes 1-year warranty on parts and labor
The EZ2 Connect MDx is intended for in vitro diagnostic use.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Purify DNA and RNA from as many as 24 samples at the same time
  • Broad application range for diagnostics and research
  • Speed, efficiency and short response time — quick turnaround and flexible throughput for handling urgent samples
  • Compliance and convenience with process safety at multiple levels to reduce risks and user errors
  • Trusted QIAGEN magnetic extraction chemistry in convenient pre-filled and sealed format
  • Comprehensive traceability with cutting edge digital connectivity

Product Details

The EZ2 Connect MDx automates prefilled cartridge-based workflows to process up to 24 clinical samples at the same time. This IVD benchtop instrument automatically pierces the sealed cartridges, heats samples for incubation, and automates pipetting of beads, buffers and even enzymes. Its intuitive touchscreen interface makes it easy to use, even for new lab workers. And with its remote connectivity features (USB, LIS and QIAsphere connection), you can monitor your runs and manage your instrument even from outside the lab.


You can process a wide range of clinical samples  (plasma, serum, cerebrospinal fluid, stool, nasopharyngeal swabs in UTM, gram-positive bacteria samples)  with dedicated DSP kits and an increasing range of research kits. EZ2 Connect MDx Kits run with preprogrammed protocols. Meet your lab’s need for throughput, time constraints, reproducibility and flexibility with EZ2 Connect MDx.

Performance

The EZ2 Connect MDx helps diagnostic labs attain a whole new level of flexibility and convenience by automating nucleic acid extraction from a wide variety of sample types for both IVD and research workflows.

Speed up your response time, increase efficiency and reduce risk of user errors. Increase your lab throughput by processing up to 24 samples all at the same time.

The EZ2 Connect MDx is also QIAsphere-ready, so you can monitor your runs and manage your instrument remotely by installing the QIAsphere app on your preferred tablet or smartphone or by accessing the QIAsphere web app through your laptop or desktop browser. The QIAGEN LIMS Connector*, an application programming interface, allows the EZ2 Connect MDx to exchange information with most common laboratory information systems (LIMs) for comprehensive traceability.

*The installation of QIAGEN LIMS Connector must be performed by a QIAGEN Representative. QIAGEN offers a dedicated service to establish the communication between the EZ2 Connect MDx and your LIMS system. If you wish QIAGEN to set up such a connection, contact your QIAGEN Sales Representative to request a quotation.

Principle

The EZ2 Connect MDx uses a piercing mechanism to open prefilled and sealed reagent cartridges. It then aspirates and dispenses samples and reagents with a 24-channel pipettor head. If heating is required during the workflow (e.g., during lysis), an on-board heating system controls the temperature of the liquids. Nucleic acid binding, washing and elution are all done automatically with in-tip magnetic bead technology (see “Expanded automation” capabilities).

Procedure

The dedicated EZ2 Connect MDx software supports quick and easy run setup using a touchscreen and preinstalled protocols. The software provides two operation modes – research and IVD. Following the illustrated instructions on the touchscreen display, the user scans a DSP kit bar code (Q-Card), chooses the suitable preinstalled protocol, loads labware and samples onto the EZ2 Connect MDx worktable and starts a run (see “EZ2 Connect MDx features”). During the run, the instrument lyses, washes, binds and elutes the nucleic acids automatically. Once the run is over, the QIAsphere App notifies the user that the run is completed, and the user returns to the machine to collect their purified nucleic acids (see “Three simple steps to isolate DNA and RNA”).

Applications

Nucleic acids purified using the EZ2 Connect MDx and the appropriate QIAGEN kits — both DSP and research (MBA) kits — can be used for sensitive analytical detection in downstream assays for IVD applications.

The EZ2 Connect MDx is compatible with EZ1 DSP Kits, EZ1&2 Kits and EZ2 Kits.

Supporting data and figures

Specifications

FeaturesSpecifications
ApplicationsAutomated nucleic acid purification in IVD and research workflows
FeaturesMagnetic-bead separation, handheld bar code reader, on-board pipetting, heating function, automated reagent-cartridge piercing, UV-LED decontamination, camera for load-check of the worktable, remote connectivity, touchscreen display, run report management, software-guided maintenance
TechnologyMagnetic-particle technology
Main sample typeWhole blood, serum, plasma, cells, tissue, FFPE tissues, liquid biopsy samples
Throughput1–24 samples
Instrument dimensions57.5 cm (22.6 in) x 72 cm (28.35 in) x 56 cm (22 in) (H x W x D) Weight: 70 kg (154.32 lb.)

Service Plans

EZ2 Connect, Preventive Subscription

Cat. No. / ID:   9245568

One on-site preventive maintenance (PM), including travel, labor and PM parts. Includes a 10% discount on repair services during the Preventive Subscription period and documentation in a GMP/GLP-compliant visit report.

EZ2 Connect, Core Agreement

Cat. No. / ID:   9245569

One on-site EZ2 Connect instrument repair service and one Preventive Maintenance or Inspection Service, including travel, labor and parts, for a period of one year. Response time of five business days. Includes a 10% discount on additional repair visits during the Core Agreement period.

EZ2 Connect, Full Agreement

Cat. No. / ID:   9245570

On-site EZ2 Connect instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

EZ2 Connect, Premium Agreement

Cat. No. / ID:   9245571

On-site EZ2 Connect instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one preventive maintenance or inspection service during the Premium Agreement period.

Resources

Operating Software (3)
EZ2 Connect Software
SOFTWARE (248MB)
Version 1.2.0

For more information on the installation process, please refer to Section 5.3.8 (Updating software) of the EZ2 Connect MDx User Manual.


Version 10 

Note: Unzip the folder prior to installation on the EZ2 Connect MDx instrument, and install the *.ez2u file only.

For more information on the installation process, please refer to Section 5.3.6. (Installing New Protocols), of the EZ2 Connect MDx User Manual.

This package contains protocols in version 5 for the EZ1 DSP Virus Kit and in version 7 for the EZ1 DSP DNA Blood Kit. Since launch of the EZ2 Connect MDx instrument, there was no change in the DSP protocols for diagnostic use.

For details on the changes, refer to "Release Note: EZ2 Connect MDx Protocol Package".
EZ2 Off The Shelf Software (OSS) License for EZ2 Connect, EZ2 Connect Fx, and EZ2 Connect MDx
Instrument User Manuals (2)
For use with software version 1.2 or higher. The EZ2 Connect MDx is intended for in vitro diagnostic use.
The EZ2 Connect MDx is intended for in vitro diagnostic use.
Previous Software Versions (2)
Version 8 (old version, compatible with software version 1.1)

For more information on the installation process, please refer to Section 5.3.6. (Installing New Protocols), of the EZ2 Connect MDx User Manual.

This package contains protocols in version 5 for the EZ1 DSP Virus Kit and in version 7 for the EZ1 DSP DNA Blood Kit. Since launch of the EZ2 Connect MDx instrument, there was no change in the DSP protocols for diagnostic use.

For details on the changes, refer to "Release Note: EZ2 Connect MDx Protocol Package".

EZ2 Connect Software
SOFTWARE (123MB)
Version 1.1.2

For more information on the installation process, please refer to Section 5.3.8 (Updating software), of the EZ2 Connect MDx User Manual. This software release contains the same protocols as version 1.1.1. For details on the contained protocol package and the software changes refer to the customer information letter on this page.
Safety Data Sheets (1)
Certificates of Analysis (1)